NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 02:33:31 on May 2, 2010
Entry number 320462
keyword=End_of_Parity_Run_3370__CODA_Config=PrexNoQweak
************************************************
Run Number: 3370
End of Run Comment:
Run_type=Test,beam_current=50,beam_energy=1.063,beam_polarization=90,beam_raster=on,comment_text=setting up for pulse tests,dithering_magnet=on,dithering_magnets=,leftarm_p=1.063,leftarm_theta=5,parity_feedback=off,parity_ihwp=out,rightarm_p=1.063,rightarm_theta=5,target_fanspeed=0 Hz,target_type=No Target, Empty
************************************************
End-of-Parity-run EPICS data for Run Number 3370 at Sun May 2 02:33:11 EDT 2010
CODA Configuration: PrexNoQweak
Compton Run Number : 22784
-----------------------------------------
Wien angle (Vertical) : -88.0006
Wien Vertical BDL (Gcm) : -2145.9
Wien HV Polarity : ON
Wien electrode Voltage : 54.966
Wien angle (Solenoids) : 89.7547
Wien BDL (First Solenoid) (Gcm) : 876
Wien BDL (Second Solenoid) (Gcm) : 857
Wien angle (Horizontal) : -51.9996
Wien BDL (Gcm) : -1193.7
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 32.828
Laser attenuation Hall A : 165
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 5500
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall B : 4.9475
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 4.95
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.476
Gun2: PC (PITA) NEG : 7.796
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : -0.05435
Pockels Cell Y Stage : -0.0372
Wager X Stage : 800
Wager Y Stage : 775
Hall A Slit Position : -0.983398
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Stable Read : 33330
Helicity Delay Read : 8 windows
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 26mW
Calculated power in cavity : -0.00197073
Photodiode on table : 0.00131753
Laser X position on QPD 1 : -221.835
Laser Y position on QPD 1 : 163.384
Laser X position on QPD 2 : 1315.84
Laser Y position on QPD 2 : 7.25044e+06
QPD 1 sum : -0.00244163
QPD 2 sum : 0.0012207
Position set point for adjustable
mirror 1 (either x or y) : -155[c]
Position set point for adjustable
mirror 2 (either x or y) : 4060[c]
Laser minimum temperature (35.8) : 32.201
Laser temperature set point : +47.121
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0433376
Gain of locking servo : 100
Tracking level (V) of locking servo : 0.08
Slow locking signal sent to laser : 0.155649
Fast locking signal sent to laser : -0.888116
Calculated polarisation in cavity : 43.9861
Photodiode 1 after Wollaston prism : 5.79462e-05
Photodiode 2 after Wollaston prism : 0.000148953
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : COMPTON_LASERT_RAMPDT --- Invalid channel name
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 582.025
Left Arm Q1 momentum : 1.0629
Left Arm Q1 gauss meter : -0.04869
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 461.84
Left Arm Q2 momentum : 1.06306
Left Arm Q2 gauss meter : 0.2429
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 353.862
Left Arm D1 momentum : 1.063
Left Arm D1 NMR : 0.393539
Left Arm Q3 power supply current : 569.988
Left Arm Q3 momentum : 1.06325
Left Arm Q3 gauss meter : -0.28768
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 582.025
Right Arm Q1 momentum : 1.063
Right Arm Q1 gauss meter : -0.014351
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 463.46
Right Arm Q2 momentum : 1.06308
Right Arm Q2 gauss meter : 0.2424
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 364.714
Right Arm D1 momentum : 1.063
Right Arm D1 NMR : 0.394467
Right Arm Q3 power supply current : 573.627
Right Arm Q3 momentum : 1.06333
Right Arm Q3 gauss meter : 0.2565
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 1.46484
Left Arm Bottom VDC Current : 1.61133
Right Arm Top VDC Current : -1.75781
Right Arm Bottom VDC Current : -1.5625
Left Arm Top VDC voltage : 0.0185547
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : -0.00634766
Right Arm Bottom VDC voltage : -0.0117188
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 2.2551
Current on Unser monitor : 17.5508
Current on Upstream bcm : 5.19297e-305
Current on Downstream bcm : 4.5102
Upstream Cavity Coefficient : 52.95
Downstream Cavity Coefficient : 44.77
Current on IBC0L02 (source) : 3.68066
Tiefenbach Hall A energy : 1055.67
Tiefenbach Hall C energy : 4085.03
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 1061.34
MBSY3c Hall C Beam energy : 4097.15
MBSY1c magnet current (amp) : 43.916
MBSY1c Bdl : 264859
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 17
Raster Y width : 7
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 12.4679
IPM1C12.YPOS : -12.916
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : 0.24
Survey Y offset bpm4A : 0.36
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : 1
Survey X offset bpm12 : 12.4679
Survey Y offset bpm12 : -12.916
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Left Arm Collimator
-----------------------------------------
Left Arm Collimator : 0.00175781
HacL_HPE1313A:0_Ch58 : -0.267578
HacL_HPE1313A:0_Ch55 : 25.1465
HacL_HPE1313A:0_Ch54 : 0.0151367
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----------------------------------------
Right Arm Collimator
-----------------------------------------
Right Arm Collimator : -0.0090332
HacR_HPE1313A:0_Ch58 : -0.637695
HacR_HPE1313A:0_Ch55 : 23.8281
HacR_HPE1313A:0_Ch54 : -0.966309
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Thick Carbon
Encoder position : 17784368
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 15.3964
pressure fill bottle H2 : 14.7494
pressure ballast H2 : 24.3534
pressure exhaust H2 : 15.0942
cryogen input temp : 198.6
crogen return flow : 7.48494
JT valve setting : 0
-----------------------------------------
PREX Left arm Det/Scint/S0 HV
-----------------------------------------
Upper Quartz : -850.7
Lower Quartz : -750.5
A_T Quartz : -998.3
Upper Scint : -5.8
Lower Scint : -20.5
S0 A : -21.3
S0 B : -21.9
-----------------------------------------
PREX Det Encoder Position
-----------------------------------------
Left Main Det x : 1.09131
Left Main Det y : 1.86719
Right Main Det x : HacH_DTC_HPE1313A:0_Ch10 --- Invalid channel name
Right Main Det y : 1.86719
-----------------------------------------
PREX Septum Currents
-----------------------------------------
Current Setpoint(Amps) : 729
Current Readback(Amps) : 725.411
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 0
No HAPPEX feedback runlog entry for Run #3370
Was feedback on?
----------------------------------------
Beamline Element Temperatures
----------------------------------------
Upstream part of W Collimator : 0.623535
Downstream part of W Collimator : 0.396484
Sieve Box : 0.33252
Beamline : 0.366699