• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name jwexler

    Log entry time 06:14:56 on May 02, 2010

    Entry number 320500

    Followups:

    keyword=Pockel cell/RHWP settings manually changed.

    Currently setting up charge feedback. Runbird returned PC +- values of ~7.5V, RHWP setting 5500. Spoke with Rupesh, manually changed to PC+ = 6.788, PC- = 8.466, RHWP = 2350. Continuing to set up feedback.