NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 11:59:30 on May 8, 2010
Entry number 321726
keyword=End_of_Parity_Run_3640__CODA_Config=Prex
************************************************
Run Number: 3640
End of Run Comment:
Run_type=Production,beam_current=50,beam_energy=1.063,beam_polarization=90,beam_raster=on,comment_text=production,dithering_magnet=on,dithering_magnets=,leftarm_p=1.063,leftarm_theta=5,parity_feedback=on,parity_ihwp=out,rightarm_p=1.063,rightarm_theta=5,target_fanspeed=0 Hz,target_type=Lead/Diamond 2
************************************************
End-of-Parity-run EPICS data for Run Number 3640 at Sat May 8 11:59:09 EDT 2010
CODA Configuration: Prex
# Timing board information: # Integrate Time = 3.58 ms, Ramp Delay = 400.00 us oversamp 1
Compton Run Number : 0
-----------------------------------------
Wien angle (Vertical) : 88.8235
Wien Vertical BDL (Gcm) : 2152.7
Wien HV Polarity : OFF
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : 89.7547
Wien BDL (First Solenoid) (Gcm) : 876
Wien BDL (Second Solenoid) (Gcm) : 857
Wien angle (Horizontal) : -51.9996
Wien BDL (Gcm) : -1194
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 32.828
Laser attenuation Hall A : 102
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 2350
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall B : 4.96459
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 4.95
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 6.318
Gun2: PC (PITA) NEG : 8.872
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : -0.05435
Pockels Cell Y Stage : -0.0372
Wager X Stage : 720
Wager Y Stage :
Hall A Slit Position : -0.979492
Helicity Clock Set : Free Clock
Helicity Delay Set : 16 windows
Helicity Pattern Set : Octet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Stable Read : 4066.65
Helicity Delay Read : 16 windows
Helicity Pattern Read : Octet
Helicity Frequency : 240.001
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power :
Calculated power in cavity : 0.00583786
Photodiode on table : 0.00539764
Laser X position on QPD 1 : -147.891
Laser Y position on QPD 1 : -108.937
Laser X position on QPD 2 : 1315.84
Laser Y position on QPD 2 : 442.478
QPD 1 sum : -0.00366241
QPD 2 sum : 0.0012207
Position set point for adjustable
mirror 1 (either x or y) : 8745[c]
Position set point for adjustable
mirror 2 (either x or y) : -35645[c]
Laser minimum temperature (35.8) : 32.201
Laser temperature set point :
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0579869
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : -4.42593
Calculated polarisation in cavity : 90.4727
Photodiode 1 after Wollaston prism : 0.000496322
Photodiode 2 after Wollaston prism : 2.48255e-05
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : COMPTON_LASERT_RAMPDT --- Invalid channel name
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 582.132
Left Arm Q1 momentum : 1.06309
Left Arm Q1 gauss meter : -0.04838
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 461.802
Left Arm Q2 momentum : 1.06298
Left Arm Q2 gauss meter : 0.2429
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 354.088
Left Arm D1 momentum : 1.06299
Left Arm D1 NMR : 0.393537
Left Arm Q3 power supply current : 569.981
Left Arm Q3 momentum : 1.06323
Left Arm Q3 gauss meter : -0.28769
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 581.491
Right Arm Q1 momentum : 1.06202
Right Arm Q1 gauss meter : -0.01437
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 463.46
Right Arm Q2 momentum : 1.06308
Right Arm Q2 gauss meter : 0.2424
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 364.749
Right Arm D1 momentum : 1.06302
Right Arm D1 NMR : 0.394476
Right Arm Q3 power supply current : 573.451
Right Arm Q3 momentum : 1.063
Right Arm Q3 gauss meter : 0.2563
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 1.46484
Left Arm Bottom VDC Current : 1.51367
Right Arm Top VDC Current : -1.70898
Right Arm Bottom VDC Current : -1.51367
Left Arm Top VDC voltage : 0.0185547
Left Arm Bottom VDC voltage : 0.019043
Right Arm Top VDC voltage : -0.00634766
Right Arm Bottom VDC voltage : -0.00732422
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 30.3031
Current on Unser monitor : 49.7046
Current on Upstream bcm : 31.1646
Current on Downstream bcm : 29.4415
Upstream Cavity Coefficient : 52.95
Downstream Cavity Coefficient : 44.77
Current on IBC0L02 (source) : 30.5083
Tiefenbach Hall A energy : 1060.52
Tiefenbach Hall C energy : 5092.65
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 1061.34
MBSY3c Hall C Beam energy : 5108.4
MBSY1c magnet current (amp) : 43.916
MBSY1c Bdl : 264859
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 9
Raster Y width : 6.6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : -0.006329
IPM1C12.YPOS : -0.0186024
IPM1H04A.XPOS : -0.0572254
IPM1H04A.YPOS : 0.0314644
IPM1H04B.XPOS : 0.0882781
IPM1H04B.YPOS : 1.05041
Survey X offset bpm4A : 0.24
Survey Y offset bpm4A : 0.36
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : 1
Survey X offset bpm12 : 0.0122407
Survey Y offset bpm12 : -0.025269
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Left Arm Collimator
-----------------------------------------
Left Arm Collimator : 0.00258789
HacL_HPE1313A:0_Ch58 : -0.276855
HacL_HPE1313A:0_Ch55 : 24.8047
HacL_HPE1313A:0_Ch54 : 0.00537109
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----------------------------------------
Right Arm Collimator
-----------------------------------------
Right Arm Collimator : -0.00917969
HacR_HPE1313A:0_Ch58 : -0.643066
HacR_HPE1313A:0_Ch55 : 23.9746
HacR_HPE1313A:0_Ch54 : -0.959473
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Pb Diamond #2
Encoder position : 28295732
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 15.4635
pressure fill bottle H2 : 14.0856
pressure ballast H2 : 24.0742
pressure exhaust H2 : 14.6853
cryogen input temp : 214
crogen return flow : 7.23378
JT valve setting : 0.0976562
-----------------------------------------
PREX Left arm Det/Scint/S0 HV
-----------------------------------------
Upper Quartz : -890.9
Lower Quartz : -791
A_T Quartz : -899.2
Upper Scint : -5.8
Lower Scint : -20.5
S0 A : -21.3
S0 B : -21.9
-----------------------------------------
PREX Det Encoder Position
-----------------------------------------
Left Main Det x : 1.09131
Left Main Det y : 1.84961
Right Main Det x : HacH_DTC_HPE1313A:0_Ch10 --- Invalid channel name
Right Main Det y : 1.84961
-----------------------------------------
PREX Septum Currents
-----------------------------------------
Current Setpoint(Amps) : 729
Current Readback(Amps) : 725.395
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_3640.log:
Cumulative stats for 720133 events:
Events failing cut conditions:
0 Low_beam 450539
1 Beam_burp 15
2 Evt_seq 0
3 Pair_seq 4
4 Startup 1
5 Adcx_DAC_burp 10
--------------------------------------------------
----------------------------------------
Beamline Element Temperatures
----------------------------------------
Upstream part of W Collimator : 3.39111
Downstream part of W Collimator : 3.64648
Sieve Box : 0.473145
Beamline : 0.820801