User name apar
Log entry time 11:08:53 on May 11, 2010
Entry number 322125
keyword=Start_Parity_Run_3725__CODA_Config=CHInj2_Run_type=Test,beam_current=0,beam_energy=1.063,beam_polarization=90,beam_raster=on,comment_text=injector studies::bpm cal,dithering_magnet=off,dithering_magnets=,leftarm_p=1.063,leftarm_theta=5,parity_feedback=off,parity_ihwp=in,rightarm_p=1.063,rightarm_theta=5,target_fanspeed=0 Hz,target_type=No Target, Empty
Beginning-of-Parity-run EPICS data for Run Number 3725 at Tue May 11 11:07:56 EDT 2010
CODA Configuration: CHInj2
# Timing board information: # Integrate Time = 7.30 ms, Ramp Delay = 400.00 us oversamp 1
Compton Run Number : 0
-----------------------------------------
Wien angle (Vertical) : -88.0006
Wien Vertical BDL (Gcm) : -2151.9
Wien HV Polarity : ON
Wien electrode Voltage : 54.966
Wien angle (Solenoids) : 89.7547
Wien BDL (First Solenoid) (Gcm) : 876
Wien BDL (Second Solenoid) (Gcm) : 857
Wien angle (Horizontal) : -51.9996
Wien BDL (Gcm) : -1201.2
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 32.828
Laser attenuation Hall A : 130
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 2350
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall B : 4.97436
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 4.95
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 6.815
Gun2: PC (PITA) NEG : 8.439
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : -0.05435
Pockels Cell Y Stage : -0.0372
Wager X Stage : 720
Wager Y Stage : 750
Hall A Slit Position : -1.00439
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Stable Read : 8233.35
Helicity Delay Read : 8 windows
Helicity Pattern Read : Quartet
Helicity Frequency : 120
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 79mW
Calculated power in cavity : 0.073614
Photodiode on table : 566.047
Laser X position on QPD 1 : 696.112
Laser Y position on QPD 1 : -76.6562
Laser X position on QPD 2 : -13.7634
Laser Y position on QPD 2 : 825.409
QPD 1 sum : -0.291766
QPD 2 sum : -0.583532
Position set point for adjustable
mirror 1 (either x or y) : 9745[c]
Position set point for adjustable
mirror 2 (either x or y) : -34075[c]
Laser minimum temperature (35.8) : 32.201
Laser temperature set point : +47.317
Polarisation in cavity : RIGHT
Reflection photodiode : 0.719648
Gain of locking servo : 125
Tracking level (V) of locking servo : 0.72
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 7.38143
Calculated polarisation in cavity : 0.257301
Photodiode 1 after Wollaston prism : 0.00380681
Photodiode 2 after Wollaston prism : 0.00378727
Step size for RHWP scan : 10625
Laser temp slow ramp (1 = on) : ON
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 582.078
Left Arm Q1 momentum : 1.063
Left Arm Q1 gauss meter : -0.04824
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 461.835
Left Arm Q2 momentum : 1.06305
Left Arm Q2 gauss meter : 0.243
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -0.00106162
Left Arm D1 momentum : 0.00324611
Left Arm D1 NMR : 0.430839
Left Arm Q3 power supply current : 569.784
Left Arm Q3 momentum : 1.06287
Left Arm Q3 gauss meter : -0.28749
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 582.185
Right Arm Q1 momentum : 1.06319
Right Arm Q1 gauss meter : -0.014325
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 463.465
Right Arm Q2 momentum : 1.06309
Right Arm Q2 gauss meter : 0.2425
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 446.797
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.265919
Right Arm Q3 power supply current : 573.456
Right Arm Q3 momentum : 1.06301
Right Arm Q3 gauss meter : 0.2562
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 1.46484
Left Arm Bottom VDC Current : 1.46484
Right Arm Top VDC Current : -1.75781
Right Arm Bottom VDC Current : -1.46484
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : -0.00634766
Right Arm Bottom VDC voltage : -0.00683594
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0272648
Current on Unser monitor : 19.4155
Current on Upstream bcm : 0.0407361
Current on Downstream bcm : 0.0137934
Upstream Cavity Coefficient : 52.95
Downstream Cavity Coefficient : 44.77
Current on IBC0L02 (source) : 0.00216085
Tiefenbach Hall A energy : 1060.52
Tiefenbach Hall C energy : 5092.65
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 1061.34
MBSY3c Hall C Beam energy : 5108.4
MBSY1c magnet current (amp) : 1.33514e-05
MBSY1c Bdl : 264859
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 9
Raster Y width : 6.6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : 0.24
Survey Y offset bpm4A : 0.36
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : 1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Left Arm Collimator
-----------------------------------------
Left Arm Collimator : 0.00170898
HacL_HPE1313A:0_Ch58 : -0.278809
HacL_HPE1313A:0_Ch55 : 24.5605
HacL_HPE1313A:0_Ch54 : 0.00488281
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----------------------------------------
Right Arm Collimator
-----------------------------------------
Right Arm Collimator : -0.000195313
HacR_HPE1313A:0_Ch58 : -0.647461
HacR_HPE1313A:0_Ch55 : 23.7305
HacR_HPE1313A:0_Ch54 : -0.964844
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Empty
Encoder position : 13395288
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 15.7183
pressure fill bottle H2 : 14.3343
pressure ballast H2 : 23.8178
pressure exhaust H2 : 14.8836
cryogen input temp : 214.3
crogen return flow : 7.10275
JT valve setting : 0
-----------------------------------------
PREX Left arm Det/Scint/S0 HV
-----------------------------------------
Upper Quartz : -776.5
Lower Quartz : -685.5
A_T Quartz : -898.4
Upper Scint : -5.8
Lower Scint : -21.3
S0 A : -21.3
S0 B : -21.9
-----------------------------------------
PREX Det Encoder Positions
-----------------------------------------
Left Main Det x : 1.09082
Left Main Det y : 1.8501
Right Main Det x : 0.441895
Right Main Det y : 1.95654
-----------------------------------------
PREX A_T Encoder Positions
-----------------------------------------
Left A_T Det x : 3.12354
Left A_T Det y : 1.80322
Right A_T Det x : 1.30811
Right A_T Det y : 3.375
-----------------------------------------
PREX Septum Currents
-----------------------------------------
Current Setpoint(Amps) : 729
Current Readback(Amps) : 0
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 0
anatype fdbk
curmon bcm3
feedback PITA on 4 bcm3
PITAparam slope -574
feedback IA off 2 bcm3
feedback PZT off 20 bpm4b
ncuts 6
cutnames Low_beam Beam_burp Evt_seq Pair_seq Startup Adcx_DAC_burp
extlo 10 10 25 25 0 10
exthi 1200 40 25 25 0 10
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/PREX/runlistDB/addRun2runlist.pl -r 3725 -d '2010-05-11 11:07:50' -t 13395288 -s IN