NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 16:00:17 on May 25, 2010
Entry number 323694
keyword=End_of_Parity_Run_4059__CODA_Config=Prex
************************************************
Run Number: 4059
End of Run Comment:
Run_type=Test,beam_current=0,beam_energy=1.063,beam_polarization=90,beam_raster=on,comment_text=linearity test setup,dithering_magnet=off,dithering_magnets=,leftarm_p=1.063,leftarm_theta=5,parity_feedback=off,parity_ihwp=in,rightarm_p=1.063,rightarm_theta=5,target_fanspeed=0 Hz,target_type=No Target, Empty
************************************************
End-of-Parity-run EPICS data for Run Number 4059 at Tue May 25 15:59:57 EDT 2010
CODA Configuration: Prex
# Timing board information: # Integrate Time = 7.30 ms, Ramp Delay = 400.00 us oversamp 1
Compton Run Number : 22912
-----------------------------------------
Wien angle (Vertical) : 88.8235
Wien Vertical BDL (Gcm) : 2133
Wien HV Polarity : OFF
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : 89.7547
Wien BDL (First Solenoid) (Gcm) : 876
Wien BDL (Second Solenoid) (Gcm) : 857
Wien angle (Horizontal) : -51.9996
Wien BDL (Gcm) : -1201
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 32.828
Laser attenuation Hall A : 90
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 2350
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall B : 4.95238
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 4.95
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 6.782
Gun2: PC (PITA) NEG : 8.472
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : -0.0396
Pockels Cell Y Stage : -0.04435
Wager X Stage : 720
Wager Y Stage : 750
Hall A Slit Position : 8
Helicity Clock Set : Free Clock
Helicity Delay Set : 16 windows
Helicity Pattern Set : Octet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Stable Read : 4066.65
Helicity Delay Read : 16 windows
Helicity Pattern Read : Octet
Helicity Frequency : 240.001
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 84mW
Calculated power in cavity : 0.0545766
Photodiode on table : 1124.79
Laser X position on QPD 1 : 654.336
Laser Y position on QPD 1 : -110.336
Laser X position on QPD 2 : -31.9724
Laser Y position on QPD 2 : 791.758
QPD 1 sum : -0.48587
QPD 2 sum : -0.653116
Position set point for adjustable
mirror 1 (either x or y) : 9695[c]
Position set point for adjustable
mirror 2 (either x or y) : -34095[c]
Laser minimum temperature (35.8) : 32.201
Laser temperature set point : +47.363
Polarisation in cavity : LEFT
Reflection photodiode : 0.658609
Gain of locking servo : 125
Tracking level (V) of locking servo : 0.58
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 7.8026
Calculated polarisation in cavity : 6.71939
Photodiode 1 after Wollaston prism : 0.00381185
Photodiode 2 after Wollaston prism : 0.00398312
Step size for RHWP scan : 10625
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : COMPTON_LASERT_RAMPDT --- Invalid channel name
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 3500
Left Arm Q1 momentum : 4.6522
Left Arm Q1 gauss meter : 0.0002407
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.0139456
Left Arm Q2 momentum : 0.00351177
Left Arm Q2 gauss meter : 0.0009424
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -0.0177222
Left Arm D1 momentum : 0.00326393
Left Arm D1 NMR : 0.466672
Left Arm Q3 power supply current : 1.15818
Left Arm Q3 momentum : 0.00761373
Left Arm Q3 gauss meter : -0.00076142
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 405.196
Right Arm Q1 momentum : 0.739971
Right Arm Q1 gauss meter : -0.010025
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.00916214
Right Arm Q2 momentum : -2.10161e-05
Right Arm Q2 gauss meter : 0.0003951
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 22.3315
Right Arm D1 momentum : 0.0574306
Right Arm D1 NMR : 0.510309
Right Arm Q3 power supply current : 0.11695
Right Arm Q3 momentum : 0.00340255
Right Arm Q3 gauss meter : 0.0003079
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 4.19922
Left Arm Bottom VDC Current : 4.83398
Right Arm Top VDC Current : -1.5625
Right Arm Bottom VDC Current : -1.51367
Left Arm Top VDC voltage : 3.99658
Left Arm Bottom VDC voltage : 4.00049
Right Arm Top VDC voltage : -0.00634766
Right Arm Bottom VDC voltage : 0.00830078
-----------------------------------------
HallA & Injector BCMs and Energy, FFB Variables
-----------------------------------------
Average current of the two cavities : 0.0267743
Current on Unser monitor : 20.1383
Current on Upstream bcm : 0.0380336
Current on Downstream bcm : 0.0155736
Upstream Cavity Coefficient : 52.95
Downstream Cavity Coefficient : 44.77
Current on IBC0L02 (source) : 0.617626
Tiefenbach Hall A energy : 1060.52
Tiefenbach Hall C energy : 5092.65
Delta(E)/E width (MV_AI_DXWID) : 1.4708
MBSY1c Hall A Beam energy : 1061.34
MBSY3c Hall C Beam energy : 5108.4
MBSY1c magnet current (amp) : 1.33514e-05
MBSY1c Bdl : 264859
FB ON, Standby, Pause status : 0
Gain OK or Gain Fail status : 0
Absolute or Relative mode : absolute
RF gain high/low : High
Gain mode: manual, automatic : manual
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 10
Raster Y width : 6.6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : 0.24
Survey Y offset bpm4A : 0.36
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : 1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Left Arm Collimator
-----------------------------------------
Left Arm Collimator : 0.00117188
HacL_HPE1313A:0_Ch58 : -0.290527
HacL_HPE1313A:0_Ch55 : 22.998
HacL_HPE1313A:0_Ch54 : -0.00292969
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----------------------------------------
Right Arm Collimator
-----------------------------------------
Right Arm Collimator : -0.00449219
HacR_HPE1313A:0_Ch58 : -0.669922
HacR_HPE1313A:0_Ch55 : 21.8262
HacR_HPE1313A:0_Ch54 : -1.00244
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Clear
Encoder position : 28295732
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 15.4665
pressure fill bottle H2 : 14.345
pressure ballast H2 : 23.3265
pressure exhaust H2 : 14.5068
cryogen input temp : 299.4
crogen return flow : 0.000701856
JT valve setting : 0
-----------------------------------------
PREX Left arm Det/Scint/S0 HV
-----------------------------------------
Upper Quartz : -866.2
Lower Quartz : -765.7
A_T Quartz : -998.3
Upper Scint : -1400.9
Lower Scint : -1700.7
S0 A : -21.3
S0 B : -22.7
-----------------------------------------
PREX Det Encoder Position
-----------------------------------------
Left Main Det x : 0.881348
Left Main Det y : 1.84912
Right Main Det x : HacH_DTC_HPE1313A:0_Ch10 --- Invalid channel name
Right Main Det y : 1.84961
-----------------------------------------
PREX Septum Currents
-----------------------------------------
Current Setpoint(Amps) : 0
Current Readback(Amps) : 0
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 0
No HAPPEX feedback runlog entry for Run #4059
Was feedback on?
----------------------------------------
Beamline Element Temperatures
----------------------------------------
Upstream part of W Collimator : 0.34375
Downstream part of W Collimator : 0.286621
Sieve Box : 0.272949
Beamline : 0.306152