NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 10:51:07 on June 4, 2010
Entry number 324482
keyword=Start_Parity_Run_4261__CODA_Config=PrexNoQweak_Run_type=Production,beam_current=50,beam_energy=1.063,beam_polarization=90,beam_raster=on,comment_text=production - 100k channels, 120Hz,dithering_magnet=on,dithering_magnets=,leftarm_p=1.063,leftarm_theta=5,parity_feedback=on,parity_ihwp=in,rightarm_p=1.063,rightarm_theta=5,target_fanspeed=0 Hz,target_type=Lead/Diamond 3 (bottom)
Beginning-of-Parity-run EPICS data for Run Number 4261 at Fri Jun 4 10:50:06 EDT 2010
CODA Configuration: PrexNoQweak
# Timing board information: # Integrate Time = 7.30 ms, Ramp Delay = 400.00 us oversamp 1
Compton Run Number : 22930
-----------------------------------------
Wien angle (Vertical) : 88.8235
Wien Vertical BDL (Gcm) : 2147.9
Wien HV Polarity : OFF
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : 89.7547
Wien BDL (First Solenoid) (Gcm) : 876
Wien BDL (Second Solenoid) (Gcm) : 857
Wien angle (Horizontal) : -51.9996
Wien BDL (Gcm) : -1204.1
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 32.828
Laser attenuation Hall A : 109
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 2350
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall B : 4.96215
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 4.95
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 6.915
Gun2: PC (PITA) NEG : 8.339
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : -0.0396
Pockels Cell Y Stage : -0.04435
Wager X Stage : 720
Wager Y Stage : 750
Hall A Slit Position : -1.00146
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Stable Read : 8233.35
Helicity Delay Read : 8 windows
Helicity Pattern Read : Quartet
Helicity Frequency : 120
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 79mW
Calculated power in cavity : 0.054939
Photodiode on table : 1621.24
Laser X position on QPD 1 : 620.839
Laser Y position on QPD 1 : -108.588
Laser X position on QPD 2 : -15.4435
Laser Y position on QPD 2 : 813.186
QPD 1 sum : -0.382103
QPD 2 sum : -0.853324
Position set point for adjustable
mirror 1 (either x or y) : 9695[c]
Position set point for adjustable
mirror 2 (either x or y) : -34095[c]
Laser minimum temperature (35.8) : 32.201
Laser temperature set point : +47.328
Polarisation in cavity : RIGHT
Reflection photodiode : 0.790453
Gain of locking servo : 120
Tracking level (V) of locking servo : 0.72
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : 7.42538
Calculated polarisation in cavity : 8.62473
Photodiode 1 after Wollaston prism : 0.0048826
Photodiode 2 after Wollaston prism : 0.00382037
Step size for RHWP scan : 10625
Laser temp slow ramp (1 = on) : ON
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 582.025
Left Arm Q1 momentum : 1.0629
Left Arm Q1 gauss meter : -0.04877
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 461.908
Left Arm Q2 momentum : 1.06322
Left Arm Q2 gauss meter : 0.2431
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 352.54
Left Arm D1 momentum : 1.063
Left Arm D1 NMR : 0.393538
Left Arm Q3 power supply current : 569.781
Left Arm Q3 momentum : 1.06286
Left Arm Q3 gauss meter : -0.28758
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 582.078
Right Arm Q1 momentum : 1.06309
Right Arm Q1 gauss meter : -0.014466
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 463.478
Right Arm Q2 momentum : 1.06313
Right Arm Q2 gauss meter : 0.2424
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 364.627
Right Arm D1 momentum : 1.063
Right Arm D1 NMR : 0.394468
Right Arm Q3 power supply current : 573.557
Right Arm Q3 momentum : 1.0632
Right Arm Q3 gauss meter : 0.2562
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 1.46484
Left Arm Bottom VDC Current : 1.51367
Right Arm Top VDC Current : -1.5625
Right Arm Bottom VDC Current : -1.46484
Left Arm Top VDC voltage : 0.0185547
Left Arm Bottom VDC voltage : 0.019043
Right Arm Top VDC voltage : -0.00634766
Right Arm Bottom VDC voltage : -0.0078125
-----------------------------------------
HallA & Injector BCMs and Energy, FFB Variables
-----------------------------------------
Average current of the two cavities : 30.5699
Current on Unser monitor : 52.2627
Current on Upstream bcm : 32.0204
Current on Downstream bcm : 29.1194
Upstream Cavity Coefficient : 52.95
Downstream Cavity Coefficient : 44.77
Current on IBC0L02 (source) : 30.2321
Tiefenbach Hall A energy : 1060.49
Tiefenbach Hall C energy : 5092.65
Delta(E)/E width (MV_AI_DXWID) : 3.48969
MBSY1c Hall A Beam energy : 1061.34
MBSY3c Hall C Beam energy : 5108.4
MBSY1c magnet current (amp) : 43.916
MBSY1c Bdl : 264859
FB ON, Standby, Pause status : 0
Gain OK or Gain Fail status : 1
Absolute or Relative mode : relative
RF gain high/low : High
Gain mode: manual, automatic : manual
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 10
Raster Y width : 6.2
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : -0.0724244
IPM1C12.YPOS : 0.135467
IPM1H04A.XPOS : -0.279696
IPM1H04A.YPOS : -0.199194
IPM1H04B.XPOS : -0.184873
IPM1H04B.YPOS : 0.948293
Survey X offset bpm4A : 0.24
Survey Y offset bpm4A : 0.36
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : 1
Survey X offset bpm12 : -0.0724244
Survey Y offset bpm12 : 0.135467
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Left Arm Collimator
-----------------------------------------
Left Arm Collimator : 0.00200195
HacL_HPE1313A:0_Ch58 : -0.291016
HacL_HPE1313A:0_Ch55 : 22.9492
HacL_HPE1313A:0_Ch54 : -0.00878906
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 29.5
Left Arm Scattering Angle : 12.491
-----------------------------------------
Right Arm Collimator
-----------------------------------------
Right Arm Collimator : -0.00410156
HacR_HPE1313A:0_Ch58 : -0.668945
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -1.00488
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.501
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Pb Diamond #3
Encoder position : 26503740
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 15.5291
pressure fill bottle H2 : 14.1711
pressure ballast H2 : 23.4226
pressure exhaust H2 : 14.3816
cryogen input temp : 219.2
crogen return flow : 8.99434
JT valve setting : 0.341797
-----------------------------------------
PREX Left arm Det/Scint/S0 HV
-----------------------------------------
Upper Quartz : -720.8
Lower Quartz : -639.7
A_T Quartz : -898.4
Upper Scint : -5.8
Lower Scint : -18.2
S0 A : -21.3
S0 B : -22.7
-----------------------------------------
PREX Det Encoder Positions
-----------------------------------------
Left Main Det x : 0.881836
Left Main Det y : 1.84912
Right Main Det x : 0.447754
Right Main Det y : 1.95801
-----------------------------------------
PREX A_T Encoder Positions
-----------------------------------------
Left A_T Det x : 3.12354
Left A_T Det y : 1.72705
Right A_T Det x : 1.30762
Right A_T Det y : 3.375
-----------------------------------------
PREX Septum Currents
-----------------------------------------
Current Setpoint(Amps) : 729
Current Readback(Amps) : 725.427
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
anatype fdbk
curmon bcm3
posmone bpm12x
feedback PITA on 4 bcm3
PITAparam slope -574
feedback IA off 2 bcm3
feedback PZT off 20 bpm12x
ncuts 7
cutnames Low_beam Beam_burp Evt_seq Pair_seq Startup Adcx_DAC_burp Pos_burp_E
extlo 10 10 25 25 0 10 50
exthi 1200 40 25 25 0 10 100
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/PREX/runlistDB/addRun2runlist.pl -r 4261 -d '2010-06-04 10:50:01' -t 26503740 -s IN