User name apar
Log entry time 01:12:46 on June 6, 2010
Entry number 324786
keyword=End_of_Parity_Run_4330__CODA_Config=CHInj2
************************************************
Run Number: 4330
End of Run Comment:
Run_type=Test,beam_current=0,beam_energy=1.063,beam_polarization=90,beam_raster=on,comment_text=Injector studies::Checking position differences PC at(-42.7,-75.1),dithering_magnet=off,dithering_magnets=,leftarm_p=1.063,leftarm_theta=5,parity_feedback=on,parity_ihwp=in,rightarm_p=1.063,rightarm_theta=5,target_fanspeed=0 Hz,target_type=Lead/Diamond 3 (bottom)
************************************************
End-of-Parity-run EPICS data for Run Number 4330 at Sun Jun 6 01:10:11 EDT 2010
CODA Configuration: CHInj2
# Timing board information: # Integrate Time = 7.30 ms, Ramp Delay = 400.00 us oversamp 1
Compton Run Number : compton:RUN --- Invalid channel name
-----------------------------------------
Wien angle (Vertical) : 88.8235
Wien Vertical BDL (Gcm) : 2147.9
Wien HV Polarity : OFF
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : 89.7547
Wien BDL (First Solenoid) (Gcm) : 876
Wien BDL (Second Solenoid) (Gcm) : 857
Wien angle (Horizontal) : -51.9996
Wien BDL (Gcm) : -1204.1
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 32.828
Laser attenuation Hall A : 135
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 2350
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall B : 4.96459
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 4.95
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 6.538
Gun2: PC (PITA) NEG : 8.652
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : -0.0427
Pockels Cell Y Stage : -0.0751
Wager X Stage : 720
Wager Y Stage : 750
Hall A Slit Position : -1.00049
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Stable Read : 8233.35
Helicity Delay Read : 8 windows
Helicity Pattern Read : Quartet
Helicity Frequency : 120
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : COMPTON_LASERP_si --- Invalid channel name
Calculated power in cavity : COMPTON_PW1PCAV_ca --- Invalid channel name
Photodiode on table : COMPTON_PW2PCAV_ca --- Invalid channel name
Laser X position on QPD 1 : COMPTON_Y1SS_ca --- Invalid channel name
Laser Y position on QPD 1 : COMPTON_X1SS_ca --- Invalid channel name
Laser X position on QPD 2 : COMPTON_Y2SS_ca --- Invalid channel name
Laser Y position on QPD 2 : COMPTON_X2SS_ca --- Invalid channel name
QPD 1 sum : COMPTON_XYSUM1_ca --- Invalid channel name
QPD 2 sum : COMPTON_XYSUM2_ca --- Invalid channel name
Position set point for adjustable
mirror 1 (either x or y) : COMPTON_POS1_si --- Invalid channel name
Position set point for adjustable
mirror 2 (either x or y) : COMPTON_POS3_si --- Invalid channel name
Laser minimum temperature (35.8) : COMPTON_LASERT_MIN --- Invalid channel name
Laser temperature set point : COMPTON_LASERT_si --- Invalid channel name
Polarisation in cavity : COMPTON_SU_POLAR_mo --- Invalid channel name
Reflection photodiode : COMPTON_SERVO_PDRai --- Invalid channel name
Gain of locking servo : COMPTON_SERVO_GAINao --- Invalid channel name
Tracking level (V) of locking servo : COMPTON_SERVO_SEUILao --- Invalid channel name
Slow locking signal sent to laser : COMPTON_SERVO_SLOWai --- Invalid channel name
Fast locking signal sent to laser : COMPTON_SERVO_FASTai --- Invalid channel name
Calculated polarisation in cavity : COMPTON_CAVPOLAR_ca --- Invalid channel name
Photodiode 1 after Wollaston prism : COMPTON_PW1R_S1_ca --- Invalid channel name
Photodiode 2 after Wollaston prism : COMPTON_PW1R_S2_ca --- Invalid channel name
Step size for RHWP scan : COMPTON_PVAL_Y_ao --- Invalid channel name
Laser temp slow ramp (1 = on) : COMPTON_CAVSLOW_bo --- Invalid channel name
Extent of laser temp slow ramp (C) : COMPTON_LASERT_RAMPDT --- Invalid channel name
Speed of laser temp slow ramp up : COMPTON_CAVPLUSOFT_ca.B --- Invalid channel name
Speed of laser temp slow ramp down : COMPTON_CAVMOINSOFT_ca.B --- Invalid channel name
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 582.078
Left Arm Q1 momentum : 1.06309
Left Arm Q1 gauss meter : -0.04876
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 461.909
Left Arm Q2 momentum : 1.06322
Left Arm Q2 gauss meter : 0.243
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 352.54
Left Arm D1 momentum : 1.06299
Left Arm D1 NMR : 0.393535
Left Arm Q3 power supply current : 569.784
Left Arm Q3 momentum : 1.06286
Left Arm Q3 gauss meter : -0.28762
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 582.078
Right Arm Q1 momentum : 1.063
Right Arm Q1 gauss meter : -0.014457
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 463.479
Right Arm Q2 momentum : 1.06313
Right Arm Q2 gauss meter : 0.2423
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 364.635
Right Arm D1 momentum : 1.06302
Right Arm D1 NMR : 0.394476
Right Arm Q3 power supply current : 573.561
Right Arm Q3 momentum : 1.06321
Right Arm Q3 gauss meter : 0.2562
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 1.51367
Left Arm Bottom VDC Current : 1.46484
Right Arm Top VDC Current : -1.85547
Right Arm Bottom VDC Current : -1.51367
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.019043
Right Arm Top VDC voltage : -0.0126953
Right Arm Bottom VDC voltage : -0.0126953
-----------------------------------------
HallA & Injector BCMs and Energy, FFB Variables
-----------------------------------------
Average current of the two cavities : 0.0259874
Current on Unser monitor : 21.5364
Current on Upstream bcm : 0.0384008
Current on Downstream bcm : 0.0135741
Upstream Cavity Coefficient : 52.95
Downstream Cavity Coefficient : 44.77
Current on IBC0L02 (source) : 0.295682
Tiefenbach Hall A energy : 1060.52
Tiefenbach Hall C energy : 5092.65
Delta(E)/E width (MV_AI_DXWID) : 3.49249
MBSY1c Hall A Beam energy : 1061.34
MBSY3c Hall C Beam energy : 5108.4
MBSY1c magnet current (amp) : 1.33514e-05
MBSY1c Bdl : 264859
FB ON, Standby, Pause status : 0
Gain OK or Gain Fail status : 0
Absolute or Relative mode : absolute
RF gain high/low : Low
Gain mode: manual, automatic : manual
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 10.2
Raster Y width : 6.5
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : 0.24
Survey Y offset bpm4A : 0.36
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : 1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Left Arm Collimator
-----------------------------------------
Left Arm Collimator : 0.00175781
HacL_HPE1313A:0_Ch58 : -0.291504
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : -0.00927734
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 29.5
Left Arm Scattering Angle : 12.491
-----------------------------------------
Right Arm Collimator
-----------------------------------------
Right Arm Collimator : -0.00410156
HacR_HPE1313A:0_Ch58 : -0.67334
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -1.01025
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.501
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Empty
Encoder position : 13395287
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 15.4894
pressure fill bottle H2 : 14.2702
pressure ballast H2 : 23.1525
pressure exhaust H2 : 14.4091
cryogen input temp : 217.2
crogen return flow : 9.21618
JT valve setting : 0.0976562
-----------------------------------------
PREX Left arm Det/Scint/S0 HV
-----------------------------------------
Upper Quartz : -720.1
Lower Quartz : -639.7
A_T Quartz : -898.4
Upper Scint : -5.8
Lower Scint : -18.2
S0 A : -21.3
S0 B : -22.7
-----------------------------------------
PREX Det Encoder Position
-----------------------------------------
Left Main Det x : 0.881348
Left Main Det y : 1.84912
Right Main Det x : HacH_DTC_HPE1313A:0_Ch10 --- Invalid channel name
Right Main Det y : 1.84961
-----------------------------------------
PREX Septum Currents
-----------------------------------------
Current Setpoint(Amps) : 0
Current Readback(Amps) : 0
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_4330.log:
Cumulative stats for 36286 events:
Events failing cut conditions:
0 Low_beam 36285
1 Beam_burp 0
2 Evt_seq 0
3 Pair_seq 1
4 Startup 1
5 Adcx_DAC_burp 0
6 Pos_burp_E 0
----------------------------------------
Beamline Element Temperatures
----------------------------------------
Upstream part of W Collimator : 0.34375
Downstream part of W Collimator : 0.335938
Sieve Box : 0.283691
Beamline : 0.325684