User name apar
Log entry time 02:47:49 on June 15, 2010
Entry number 326627
keyword=Start_Parity_Run_4563__CODA_Config=Prex_Run_type=Production,beam_current=50,beam_energy=1.063,beam_polarization=90,beam_raster=on,comment_text=momentum up 7%, higher high voltage,dithering_magnet=on,dithering_magnets=,leftarm_p=1.063,leftarm_theta=5,parity_feedback=on,parity_ihwp=in,rightarm_p=1.063,rightarm_theta=5,target_fanspeed=0 Hz,target_type=Lead/Diamond 1 (top)
Beginning-of-Parity-run EPICS data for Run Number 4563 at Tue Jun 15 02:44:41 EDT 2010
CODA Configuration: Prex
# Timing board information: # Integrate Time = 7.78 ms, Ramp Delay = 400.00 us oversamp 1
Compton Run Number : compton:RUN --- Invalid channel name
-----------------------------------------
Wien angle (Vertical) : 88.8235
Wien Vertical BDL (Gcm) : 2147.9
Wien HV Polarity : OFF
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : 89.7547
Wien BDL (First Solenoid) (Gcm) : 876
Wien BDL (Second Solenoid) (Gcm) : 857
Wien angle (Horizontal) : -51.9996
Wien BDL (Gcm) : -1199.8
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 32.828
Laser attenuation Hall A : 139
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 2350
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall B : 4.97436
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 4.95
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 6.864
Gun2: PC (PITA) NEG : 8.39
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : -0.04265
Pockels Cell Y Stage : -0.0751
Wager X Stage : 720
Wager Y Stage : 750
Hall A Slit Position : -1.00049
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Stable Read : 8233.35
Helicity Delay Read : 8 windows
Helicity Pattern Read : Quartet
Helicity Frequency : 120
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : COMPTON_LASERP_si --- Invalid channel name
Calculated power in cavity : COMPTON_PW1PCAV_ca --- Invalid channel name
Photodiode on table : COMPTON_PW2PCAV_ca --- Invalid channel name
Laser X position on QPD 1 : COMPTON_Y1SS_ca --- Invalid channel name
Laser Y position on QPD 1 : COMPTON_X1SS_ca --- Invalid channel name
Laser X position on QPD 2 : COMPTON_Y2SS_ca --- Invalid channel name
Laser Y position on QPD 2 : COMPTON_X2SS_ca --- Invalid channel name
QPD 1 sum : COMPTON_XYSUM1_ca --- Invalid channel name
QPD 2 sum : COMPTON_XYSUM2_ca --- Invalid channel name
Position set point for adjustable
mirror 1 (either x or y) : COMPTON_POS1_si --- Invalid channel name
Position set point for adjustable
mirror 2 (either x or y) : COMPTON_POS3_si --- Invalid channel name
Laser minimum temperature (35.8) : COMPTON_LASERT_MIN --- Invalid channel name
Laser temperature set point : COMPTON_LASERT_si --- Invalid channel name
Polarisation in cavity : COMPTON_SU_POLAR_mo --- Invalid channel name
Reflection photodiode : COMPTON_SERVO_PDRai --- Invalid channel name
Gain of locking servo : COMPTON_SERVO_GAINao --- Invalid channel name
Tracking level (V) of locking servo :
Slow locking signal sent to laser : COMPTON_SERVO_SLOWai --- Invalid channel name
Fast locking signal sent to laser : COMPTON_SERVO_FASTai --- Invalid channel name
Calculated polarisation in cavity : COMPTON_CAVPOLAR_ca --- Invalid channel name
Photodiode 1 after Wollaston prism : COMPTON_PW1R_S1_ca --- Invalid channel name
Photodiode 2 after Wollaston prism : COMPTON_PW1R_S2_ca --- Invalid channel name
Step size for RHWP scan : COMPTON_PVAL_Y_ao --- Invalid channel name
Laser temp slow ramp (1 = on) : COMPTON_CAVSLOW_bo --- Invalid channel name
Speed of laser temp slow ramp up : COMPTON_CAVPLUSOFT_ca.B --- Invalid channel name
Speed of laser temp slow ramp down : COMPTON_CAVMOINSOFT_ca.B --- Invalid channel name
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 582.078
Left Arm Q1 momentum : 1.063
Left Arm Q1 gauss meter : -0.04874
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 461.813
Left Arm Q2 momentum : 1.063
Left Arm Q2 gauss meter : 0.2429
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 389.253
Left Arm D1 momentum : 1.16978
Left Arm D1 NMR : 0.433069
Left Arm Q3 power supply current : 569.941
Left Arm Q3 momentum : 1.06316
Left Arm Q3 gauss meter : -0.28781
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 582.185
Right Arm Q1 momentum : 1.06319
Right Arm Q1 gauss meter : -0.014358
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 463.424
Right Arm Q2 momentum : 1.063
Right Arm Q2 gauss meter : 0.24164
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 364.604
Right Arm D1 momentum : 1.06309
Right Arm D1 NMR : 0.394501
Right Arm Q3 power supply current : 573.422
Right Arm Q3 momentum : 1.06295
Right Arm Q3 gauss meter : 0.25627
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.51367
Right Arm Top VDC Current : -1.66016
Right Arm Bottom VDC Current : -1.51367
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.019043
Right Arm Top VDC voltage : -0.0117188
Right Arm Bottom VDC voltage : -0.0117188
-----------------------------------------
HallA & Injector BCMs and Energy, FFB Variables
-----------------------------------------
Average current of the two cavities : 48.6481
Current on Unser monitor : 71.1399
Current on Upstream bcm : 51.1984
Current on Downstream bcm : 46.0977
Upstream Cavity Coefficient : 52.95
Downstream Cavity Coefficient : 44.77
Current on IBC0L02 (source) : 5.12714
Tiefenbach Hall A energy : 1060.53
Tiefenbach Hall C energy : 5092.66
Delta(E)/E width (MV_AI_DXWID) : 4.21181
MBSY1c Hall A Beam energy : 1061.34
MBSY3c Hall C Beam energy : 5108.41
MBSY1c magnet current (amp) : 43.916
MBSY1c Bdl : 264859
FB ON, Standby, Pause status : 0
Gain OK or Gain Fail status : 0
Absolute or Relative mode : absolute
RF gain high/low : Low
Gain mode: manual, automatic : manual
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 23
Raster Y width : 9.5
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : -0.011226
IPM1C12.YPOS : 0.149974
IPM1H04A.XPOS : 0.0364083
IPM1H04A.YPOS : -0.12315
IPM1H04B.XPOS : -0.0257674
IPM1H04B.YPOS : 0.592276
Survey X offset bpm4A : 0.24
Survey Y offset bpm4A : 0.36
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : 1
Survey X offset bpm12 : -0.011226
Survey Y offset bpm12 : 0.149974
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Left Arm Collimator
-----------------------------------------
Left Arm Collimator : 0.00214844
HacL_HPE1313A:0_Ch58 : -0.300293
HacL_HPE1313A:0_Ch55 : 22.9492
HacL_HPE1313A:0_Ch54 : -0.0292969
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 29.5
Left Arm Scattering Angle : 12.491
-----------------------------------------
Right Arm Collimator
-----------------------------------------
Right Arm Collimator : -0.000976562
HacR_HPE1313A:0_Ch58 : -0.684082
HacR_HPE1313A:0_Ch55 : 21.5332
HacR_HPE1313A:0_Ch54 : -1.02686
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Pb Diamond #1
Encoder position : 30087740
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 15.6374
pressure fill bottle H2 : 14.3465
pressure ballast H2 : 23.0014
pressure exhaust H2 : 14.9401
cryogen input temp : 216.8
crogen return flow : 9.18281
JT valve setting : 0
-----------------------------------------
PREX Left arm Det/Scint/S0 HV
-----------------------------------------
Upper Quartz : -1000.7
Lower Quartz : -901
A_T Quartz : -898.4
Upper Scint : -5.8
Lower Scint : -11.3
S0 A : -21.3
S0 B : -22.7
-----------------------------------------
PREX Det Encoder Positions
-----------------------------------------
Left Main Det x : 0.999512
Left Main Det y : 1.84961
Right Main Det x : 0.356934
Right Main Det y : 1.95752
-----------------------------------------
PREX A_T Encoder Positions
-----------------------------------------
Left A_T Det x : 3.12402
Left A_T Det y : 1.72705
Right A_T Det x : 1.30713
Right A_T Det y : 3.37549
-----------------------------------------
PREX Septum Currents
-----------------------------------------
Current Setpoint(Amps) : 729
Current Readback(Amps) : 725.411
-----------------------------------------
Moeller Magnet Currents
-----------------------------------------
Moeller ON/OFF : disabled
MQM1H02 Setpoint(Amps) : 48.3044
MQM1H02 Readback(Amps) : 47.1429
MQO1H03 Setpoint(Amps) : 1.33226
MQO1H03 Readback(Amps) : 1.20879
MQO1H03A Setpoint(Amps) : -60.7113
MQO1H03A Readback(Amps) : -59.4725
MMA1H01 Setpoint(Amps) : 0
MMA1H01 Readback(Amps) : 0
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
anatype fdbk
curmon bcm3
posmone bpm12x
feedback PITA on 4 bcm3
PITAparam slope -574
feedback IA off 2 bcm3
feedback PZT off 20 bpm12x
ncuts 7
cutnames Low_beam Beam_burp Evt_seq Pair_seq Startup Adcx_DAC_burp Pos_burp_E
extlo 10 10 25 25 0 10 50
exthi 1200 40 25 25 0 10 100
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/PREX/runlistDB/addRun2runlist.pl -r 4563 -d '2010-06-15 02:44:33' -t 30087740 -s IN