• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name R. Michaels

    Log entry time 05:33:59 on June18,2010

    Entry number 327212

    keyword=Ramping to 70 uA

    Time .... Current .... Run .... Collim temps .... vacuum
    ........... uA .................. degr. C ......... Torr

    05:00 .... 50 .... 4652 .... 220 / 249 ..... 1.2e-6

    05:06 .... 55 .... same .... 287 / 278 ..... 1.1e-6

    05:18 .... 60 .... same .... 312 / 300 ..... 1.1e-6

    05:23 .... 65 .... same .... 335 / 306 ..... 1.2e-6

    05:26 .... 70 .... same .... 345 / 314 ..... 1.1e-6

    05:31 ... Unrelated to this test, the ACC has a problem:
    vacuum in East arc.

    So Bob will go home to sleep and has given instructions
    to the shift to watch the temps and vacuum.

    If collim = 600 C, stop beam
    If vacuum = 8e-5 Torr, stop beam
    If beampipe = 200 C stop beam.