User name R. Michaels
Log entry time 05:33:59 on June18,2010
Entry number 327212
keyword=Ramping to 70 uA
Time .... Current .... Run .... Collim temps .... vacuum
........... uA .................. degr. C ......... Torr
05:00 .... 50 .... 4652 .... 220 / 249 ..... 1.2e-6
05:06 .... 55 .... same .... 287 / 278 ..... 1.1e-6
05:18 .... 60 .... same .... 312 / 300 ..... 1.1e-6
05:23 .... 65 .... same .... 335 / 306 ..... 1.2e-6
05:26 .... 70 .... same .... 345 / 314 ..... 1.1e-6
05:31 ... Unrelated to this test, the ACC has a problem:
vacuum in East arc.
So Bob will go home to sleep and has given instructions
to the shift to watch the temps and vacuum.
If collim = 600 C, stop beam
If vacuum = 8e-5 Torr, stop beam
If beampipe = 200 C stop beam.