• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 04:53:29 on June 26, 2010

    Entry number 328303

    keyword=End_of_Run_1105
    ****************************
     Run Number: 1105
     End of Run Comment:
    Run_type=Calibration,target_type=BeO,beam_e0=1.063,beam_raster=on,beam_current=2,leftarm_p=1.063,leftarm_theta=5.0,leftarm_sieve=out,rightarm_p=1.063,rightarm_theta=5.0,rightarm_sieve=out,comment_text=
     
    
    PRESCALE FACTORS:can't read "psfacline": no such variable
        while executing
    "$w insert end "$psfacline..."
        (procedure "halla_scaler_process" line 296)
        invoked from within
    "halla_scaler_process .mid.tex scalerinfo "
    
    ****************************
    End-of-run EPICS data for Run Number 1105 at Sat Jun 26 04:53:19 EDT 2010
    
    Left Arm Top VDC Current : 4.10156
    Left Arm Bottom VDC Current : 3.07617
    Left Arm Top VDC voltage : 3.50732
    Left Arm Bottom VDC voltage : 3.49902
    -----
    Right Arm Top VDC Current : -1.51367
    Right Arm Bottom VDC Current : -1.41602
    Right Arm Top VDC voltage : -0.00732422
    Right Arm Bottom VDC voltage : -0.00878906
    -----
    Left Arm Q1 momentum : 0.559852
    Left Arm Q1 power supply : 280.491
    Left Arm Q1 gauss meter : -0.02342
    Left Arm Q2 gauss meter : 0.12054
    Left Arm Q2 power supply current : 228.857
    Left Arm Q2 momentum : 0.560098
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 183.583
    Left Arm D1 momentum : 0
    Left Arm D1 NMR : 0.390657
    Left Arm arm angle : -0.179
    Left Arm Q3 gauss meter : -0.135803
    Left Arm Q3 power supply current : 268.86
    Left Arm Q3 momentum : 0.559848
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 0.00538176
    Right Arm Q1 power supply : 1.6022
    Right Arm Q1 gauss meter : -0.0001215
    Right Arm Q2 power supply current : 0.00370479
    Right Arm Q2 momentum : 0.000705383
    Right Arm Q2 gauss meter : 0.0001396
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 1.90481
    Right Arm D1 momentum : 0.00763088
    Right Arm D1 NMR : 0.166119
    Right Arm arm angle : 0.197
    Right Arm Q3 power supply current : -0.000549237
    Right Arm Q3 momentum : -1.14052e-06
    Right Arm Q3 gauss meter : 0.0002594
    Right Arm Q3 power supply polarity : enabled
    -----
    Average current of the two cavities : 2.16085
    Current on Unser monitor : 24.2585
    Current on Upstream bcm : 2.29505
    Current on Downstream bcm : 2.02665
    Upstream Cavity Coefficient : 52.95
    Downstream Cavity Coefficient : 44.77
    Current on IBC0L02 (source) : 2.40312
    Hall C Current : 0
    MBSY1c magnet current (amp) : 48.1354
    MBSY1c Bdl : 289952
    Hall A momentum (Tiefenbach) (HALLA:p) : 1160.96
    Hall A momentum orbit correction (dpp) : -2.51901e-06
    Hall A setup momentum (MMSHLAE) : 1161.88
    Hall A energy (halla_MeV) : 1160.96
    Hall C energy (hallc_MeV) : 2257.17
    Delta(E)/E width (MV_AI_DXWID) : 5.57875
    IPM1C12.XPOS : -0.00511485
    IPM1H04A.XPOS : 0.241424
    IPM1H04A.YPOS : -0.322137
    IPM1H04B.XPOS : 0.00745136
    IPM1H04B.YPOS : 0.604721
    -----
    Wien angle (Vertical) : 88.8235
    Wien Vertical BDL (Gcm) : 2147.9
    Wien HV Polarity : OFF
    Wien electrode Voltage : 55.48
    Wien angle (Solenoids) : -89.7547
    Wien BDL (First Solenoid) (Gcm) : -876
    Wien BDL (Second Solenoid) (Gcm) : -857
    Wien angle (Horizontal) : -51.9996
    Wien BDL (Gcm) : -1198.62
    Wien HV Polarity (Horizontal) : ON
    Wien electrode Voltage (Horizontal) : 32.828
    Laser attenuation Hall A : 75
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 2000
    Beam Half-wave plate (off=out) : IN
    -----
    Helicity Delay Set : 8 windows
    Helicity Pattern Set : Quartet
    Helicity Clock Set : Free Clock
    Helicity Settle Read : 60
    Helicity Stable Read : 1000
    Helicity Delay Read : 8 windows
    Helicity Pattern : Quartet
    Helicity Clock Read : Free Clock
    Helicity Frequency : 943.396
    -----
    Target : BeO Viewer
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : 2.21735e+07
    Target type : 2.21735e+07
    temperature loop 1(1) : 119.99
    temperature loop 1(2) : 119.99
    temperature loop 1(3) : 119.99
    temperature loop 3(1) : 0
    temperature loop 3(2) : 0
    temperature loop 3(3) : 0
    Heat exchange LH2 : 115.3
    Heat exchange LH2 : 278.9
    HPH H2 loop 1 : 0.0970926
    HPH H2 loop 3 : 0.00293052
    Left Det/Scint/S0 HV
    Upper Quartz : -1499.9
    Lower Quartz : -1501.3
    A_T Quartz : -1497.3
    Upper Scint : -11.1
    Lower Scint : -21.3
    S0 A : -901.6
    S0 B : -901.9
    -----
    Det Encoder Position for PREX
    Left Main Det x : 0.00683594
    Left Main Det y : 0.0126953
    Right Main Det x : HacH_DTC_HPE1313A:0_Ch10 --- Invalid channel name
    Right Main Det y : 0.0131836
    -----
    PREX Septum
    Current Setpoint(Amps) : 384.045
    Current Readback(Amps) : 382.14
    -----