    User name Bob / Bogdan

    Log entry time 23:25:33 on July 1,2010

    Entry number 329357

    keyword=R-HRS gate / timing adjustment

    Bogdan adjusted the timing of the ADC gates on R-HRS.

    Front panel gates were enabled on all 5 ADCs in the system, but
    there was a glitch: ROC1 slot 24 does not see it's front panel
    gate. I verified by swapping cables around that the gate is
    definitely there, but the module does not see it. However it
    does see the back panel gate and that's how I'll leave it overnight
    so that the rest of the crate is happy. I'll swap out this ADC
    tomorrow morning.

    Except for that glitch, I think the trigger and DAQ are finished.