NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 05:22:18 on July 11, 2010
Entry number 331418
keyword=End_of_Run_2040
****************************
Run Number: 2040
End of Run Comment:
Run_type=Production,target_type=Tantalum,beam_e0=2.261,beam_raster=on,beam_current=120,leftarm_p=1.131,leftarm_theta=5.0,leftarm_sieve=out,rightarm_p=1.131,rightarm_theta=5.0,rightarm_sieve=out,comment_text=Raster 4x6, A&B laser mix, 120 uA
PRESCALE FACTORS:ps1=4510 ps2=100000 ps3=850 ps4=10 ps5=65535 ps6=1 ps7=65535 ps8=100
EVENTS : [0]: 499105
TIME : [0]: 46.642 mins
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 4.35%
TRIGGER RATES: PRES/REAL
T1[0] :48.5/218599.1 Hz T2[0] : 1.7/166649.9 Hz T3[0] :49.8/42302.1 Hz T4[0] :42.5/425.4 Hz T5[0] : 1.8/119344.3 Hz T6[0] :31.9/31.9 Hz T7[0] : 0.0/0.0 Hz T8[0] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 135645/611760156 T2[0] : 4663/466377925 T3[0] : 139275/118384444 T4[0] : 119059/1190590 T5[0] : 5096/333990818 T6[0] : 89404/89404 T7[0] : 0/0 T8[0] : 28657/2865714
AVERAGE CURRENT
BCM x1 : 125.2702uA BCM x3 : 19.0885uA BCM x10: -21.5334uA
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.2295 BCM u3 [0]:0.2409 BCM u10[0]:-0.06521
BCM d1 [0]:0.4716 BCM d3 [0]:-0.134 BCM d10[0]:-0.05532
****************************
End-of-run EPICS data for Run Number 2040 at Sun Jul 11 05:22:08 EDT 2010
Left Arm Top VDC Current : 0.976562
Left Arm Bottom VDC Current : -0.830078
Left Arm Top VDC voltage : 3.49512
Left Arm Bottom VDC voltage : 3.49951
-----
Right Arm Top VDC Current : 0.732422
Right Arm Bottom VDC Current : -2.00195
Right Arm Top VDC voltage : 3.49512
Right Arm Bottom VDC voltage : 3.49463
-----
Left Arm Q1 momentum : 1.13058
Left Arm Q1 power supply : 566.43
Left Arm Q1 gauss meter : -0.04765
Left Arm Q2 gauss meter : 0.2431
Left Arm Q2 power supply current : 462.069
Left Arm Q2 momentum : 1.13086
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 376.555
Left Arm D1 momentum : 1.13101
Left Arm D1 NMR : 0.4187
Left Arm arm angle : 12.5054
Left Arm Q3 gauss meter : -0.27411
Left Arm Q3 power supply current : 543.132
Left Arm Q3 momentum : 1.13096
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.13091
Right Arm Q1 power supply : 565.309
Right Arm Q1 gauss meter : 0.014162
Right Arm Q2 power supply current : 462.09
Right Arm Q2 momentum : 1.13101
Right Arm Q2 gauss meter : -0.2422
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 389.166
Right Arm D1 momentum : 1.13099
Right Arm D1 NMR : 0.419695
Right Arm arm angle : 12.501
Right Arm Q3 power supply current : 544.614
Right Arm Q3 momentum : 1.13092
Right Arm Q3 gauss meter : -0.2451
Right Arm Q3 power supply polarity : enabled
-----
Average current of the two cavities : 113.455
Current on Unser monitor : 139.048
Current on Upstream bcm : 120.186
Current on Downstream bcm : 106.724
Upstream Cavity Coefficient : 52.95
Downstream Cavity Coefficient : 44.77
Current on IBC0L02 (source) : 119.528
Hall C Current : 0
MBSY1c magnet current (amp) : 94.1787
MBSY1c Bdl : 564757
Hall A momentum (Tiefenbach) (HALLA:p) : 2260.34
Hall A momentum orbit correction (dpp) : -9.79644e-06
Hall A setup momentum (MMSHLAE) : 2261.88
Hall A energy (halla_MeV) : 2260.34
Hall C energy (hallc_MeV) : 1161.32
Delta(E)/E width (MV_AI_DXWID) : 4.0571
IPM1C12.XPOS : -0.00154361
IPM1H04A.XPOS : -6.49521
IPM1H04A.YPOS : 2.43775
IPM1H04B.XPOS : -6.51924
IPM1H04B.YPOS : 2.53455
-----
Wien angle (Vertical) : 88.8235
Wien Vertical BDL (Gcm) : 2147.9
Wien HV Polarity : OFF
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : -89.7547
Wien BDL (First Solenoid) (Gcm) : -876
Wien BDL (Second Solenoid) (Gcm) : -857
Wien angle (Horizontal) : -73.8001
Wien BDL (Gcm) : -1668.2
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 46.591
Laser attenuation Hall A : 252
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 1875
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 60
Helicity Stable Read : 1000
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 943.396
-----
Target : Tantalum
fan frequency loop 1 : 0
fan frequency loop 3 : 0
Encoder position : 2.07105e+07
Target type : 2.07105e+07
temperature loop 1(1) : 119.99
temperature loop 1(2) : 119.99
temperature loop 1(3) : 119.99
temperature loop 3(1) : 0
temperature loop 3(2) : 0
temperature loop 3(3) : 0
Heat exchange LH2 : 115.3
Heat exchange LH2 : 278.9
HPH H2 loop 1 : 0.0970926
HPH H2 loop 3 : 0.00634721
Det Encoder Position for PREX
Left Main Det x : 0.0629883
Left Main Det y : 0.00732422
Right Main Det x : HacH_DTC_HPE1313A:0_Ch10 --- Invalid channel name
Right Main Det y : 0.00585938
-----
PREX Septum
Current Setpoint(Amps) : 775.6
Current Readback(Amps) : 771.81
-----