    User name a-onl

    Log entry time 16:54:13 on August 12, 2010

    Entry number 331816

    keyword=End_of_Run_6072
    ****************************
     Run Number: 6072
     End of Run Comment:
    Run_type=Cosmics,target_type=No Target, Empty,beam_e0=2.261,beam_raster=on,beam_current=150,leftarm_p=1.131,leftarm_theta=5.0,leftarm_sieve=out,rightarm_p=1.131,rightarm_theta=5.0,rightarm_sieve=out,comment_text=Test low rate - 7 boards - FIFO checks on
     
    
    PRESCALE FACTORS:can't read "psfacline": no such variable
        while executing
    "$w insert end "$psfacline..."
        (procedure "halla_scaler_process" line 289)
        invoked from within
    "halla_scaler_process .mid.tex scalerinfo "
    
    ****************************
    End-of-run EPICS data for Run Number 6072 at Thu Aug 12 16:53:58 EDT 2010
    
    Left Arm Top VDC Current : -1.85547
    Left Arm Bottom VDC Current : 3.4668
    Left Arm Top VDC voltage : 3.99561
    Left Arm Bottom VDC voltage : 3.99414
    -----
    Right Arm Top VDC Current : 0.683594
    Right Arm Bottom VDC Current : -1.26953
    Right Arm Top VDC voltage : 3.99902
    Right Arm Bottom VDC voltage : 3.99463
    -----
    Left Arm Q1 momentum : 0.000291021
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0003276
    Left Arm Q2 gauss meter : 0.0002049
    Left Arm Q2 power supply current : -0.000344429
    Left Arm Q2 momentum : -7.69648e-07
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 0.00072919
    Left Arm D1 momentum : 0.00250341
    Left Arm D1 NMR : 0.443412
    Left Arm arm angle : 12.5054
    Left Arm Q3 gauss meter : 0.00061368
    Left Arm Q3 power supply current : -0.000759832
    Left Arm Q3 momentum : -1.5822e-06
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00220042
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -6.15e-05
    Right Arm Q2 power supply current : -0.000384529
    Right Arm Q2 momentum : -5.75614e-07
    Right Arm Q2 gauss meter : -0.0007532
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : -0.000928415
    Right Arm D1 momentum : 0.00287139
    Right Arm D1 NMR : 0.211363
    Right Arm arm angle : 0.197
    Right Arm Q3 power supply current : 0.000138243
    Right Arm Q3 momentum : 0.000541251
    Right Arm Q3 gauss meter : -0.0003967
    Right Arm Q3 power supply polarity : enabled
    -----
    Average current of the two cavities : 0.025186
    Current on Unser monitor : 22.9307
    Current on Upstream bcm : 0.0356463
    Current on Downstream bcm : 0.0147257
    Upstream Cavity Coefficient : 52.95
    Downstream Cavity Coefficient : 44.77
    Current on IBC0L02 (source) : 0.0154374
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377197
    MBSY1c Bdl : 565057
    Hall A momentum (Tiefenbach) (HALLA:p) : 2261.56
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 3361.88
    Hall A energy (halla_MeV) : 2261.56
    Hall C energy (hallc_MeV) : 1160.92
    Delta(E)/E width (MV_AI_DXWID) : 4.13431
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Wien angle (Vertical) : -0
    Wien Vertical BDL (Gcm) : -2.245
    Wien HV Polarity : ON
    Wien electrode Voltage : 0
    Wien angle (Solenoids) : -3.04612
    Wien BDL (First Solenoid) (Gcm) : -1012
    Wien BDL (Second Solenoid) (Gcm) : 1012
    Wien angle (Horizontal) : -0
    Wien BDL (Gcm) : -8.854
    Wien HV Polarity (Horizontal) : ON
    Wien electrode Voltage (Horizontal) : 0
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1000
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Delay Set : 8 windows
    Helicity Pattern Set : Quartet
    Helicity Clock Set : Free Clock
    Helicity Settle Read : 60
    Helicity Stable Read : 1000
    Helicity Delay Read : 8 windows
    Helicity Pattern : Quartet
    Helicity Clock Read : Free Clock
    Helicity Frequency : 943.396
    -----
    Target : Tantalum
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : 0
    Target type : 0
    temperature loop 1(1) : 119.99
    temperature loop 1(2) : 119.99
    temperature loop 1(3) : 119.99
    temperature loop 3(1) : 0
    temperature loop 3(2) : 0
    temperature loop 3(3) : 0
    Heat exchange LH2 : 115.3
    Heat exchange LH2 : 278.9
    HPH H2 loop 1 : 39.1884
    HPH H2 loop 3 : 63.0172
    Det Encoder Position for PREX
    Left Main Det x : -0.0175781
    Left Main Det y : 0.00292969
    Right Main Det x : HacH_DTC_HPE1313A:0_Ch10 --- Invalid channel name
    Right Main Det y : 0.0229492
    -----
    PREX Septum
    Current Setpoint(Amps) : 0
    Current Readback(Amps) : 0
    -----