User name R. Michaels
Log entry time 09:22:23 on October 1,2010
Entry number 333288
This entry is a followup to: 333270
Followups:
keyword=roc4 missing a gate AGAIN
There is a gate missing in slot 23 in roc4. I suppose a cable
got knocked out -- AGAIN. We need to get better at finding out
about this and at avoiding it. The cables should be secured in
such a way that they don't fall out.
Note, the datascan word is 0x03411ff8
(in the data dump below) while the normal word is 0x03c11ff8.
These always come in a certain fixed location after the header
0xfabc0008. The datascan shows the bits corresponding to what
Fastbus slots got a gate. Bit 0 is the first and bit N means
slot N, so the missing bit is slot 23.
While I'm at it, the ROC3 normal datascan word is 0x03800ff8.
I guess we need some software that compares to normal and tells
the poor user what cable they knocked out.
Here is the roc4 data dump for run 6891. See the 3411ff8.
0xdc0000ff 0xfabc0008 0x00000064 0x03411ff8 0x00000004 0x00000004 0x00000005 0x00000004 0x00c9eb46 0x00000000 0xfaaa0001 0xfabb0000