run number : 75 pulser frquency 2Hz firmware : E05(beta) board number : 8 suppression of the jitter forgot channel 0 end can be bad because I have reprogramming the firmware without stop the RUN run number : 76 pulser frquency 2Hz firmware : E05(beta) board number : 8 forgot channel 0 run number : 77 pulser frquency 2Hz firmware : E05(beta) board number : 8 hardware modification : put an other mezzanine ARS in channel 0 to 3 same problem : forgot channel run number : 78 pulser frquency 2Hz firmware : E05(beta) board number : 8 forgot channel 0 end can be bad because I have reprogramming the firmware without stop the RUN run number : 79 pulser frquency 2Hz firmware : E05(beta) board number : 8 bad pb of the new firmware run number : 81 pulser frquency 2Hz firmware : E05(beta) board number : 8 return to previous firmware forgot channel 0 run number : 82 pulser frquency 2Hz firmware : E05(beta) board number : 8 forgot channel 0 run number : 83 pulser frquency 2Hz firmware : E05(beta) board number : 8 forgot channel 0 test to sustract the 0 at he begin in 8 channels bad result now 12 channels with 0 at begin run number : 84 pulser frquency 2Hz firmware : E05(beta) board number : 8 forgot channel 0 test to sustract the 0 at he begin in 8 channels result now 4 channels with 0 at begin run number : 85 pulser frquency 2Hz firmware : E05(beta) board number : 8 bad pb of the new firmware run number : 86 pulser frquency 2Hz firmware : E05(beta) board number : 8 test with return to run 84 configuration run number : 86 pulser frquency 2Hz firmware : E05(beta) board number : 8 test to verification input channel ARS and Display data test pulse: input 1 to arround event 140 2 to arround event 170 3 to arround event 200 4 to arround event 260 5 to arround event 290 6 to arround event 320 7 to arround event 340 8 to arround event 370 9 to arround event 390 10 to arround event 410 11 to arround event 430 12 to arround event 450 14 to arround event 480 15 to arround event 500 1 to arround event 630 13 to arround event 650 1 to arround event END RUN RUN OK after 5164 event run stop at 5859 validation of this firmware in archive E05 create a new revision E06 : goal find the channel 0 run number : 88 pulser frquency 2Hz firmware : E06(beta) board number : 8 forgot channel 0 but data stable after 32000evt run number : 89 pulser frquency 2Hz firmware : E06(beta) board number : 8 bad forgot adding trigger after download run number : 90 pulser frquency 2Hz firmware : E06(beta) board number : 8 bad firmware, 0 in all the channel run number : 91 pulser frquency 2Hz firmware : E06(beta) board number : 8 forgot channel 0 , others channel well end can be bad because I have reprogramming the firmware without stop the RUN run number : 92 pulser frquency 2Hz firmware : E06(beta) board number : 8 forgot channel 0 , others channel well a night run after 664334 event : the display is very stable for all the channel the data synchronisation is is well all the time