• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name A. Camsonne

    Log entry time 22:23:55 on October 13, 2010

    Entry number 334745

    keyword=coda EB seg faulting at end of run

    Most likely some issues in event synchronization. Event builder segfaults at the end of each run, so you need to restart it to be able to end/start another run by typing :

    coda_eb -n EB2

    -------------------

    Activating (C) daLogMsg: Activating (C) Got control event fragments type = 18 node_ix=6 Build control event: go(stream4, stream0, stream3, stream5, stream1, stream2) -- Got all fragments of go socket 24 closed thread exit for TS11 Event (Num 128 type 5) NUMBER mismatch -- stream5 (rocid 14) sent -1 (type 20) daLogMsg: Event (Num 128 type 5) NUMBER mismatch -- stream5 (rocid 14) sent -1 (type 20) Discard data until next control event daLogMsg: Discard data until next control event Found sync point 20 for ROC stream5 daLogMsg: Found sync point 20 for ROC stream5 Found sync point 20 for ROC stream1 daLogMsg: Found sync point 20 for ROC stream1 Found sync point 20 for ROC stream2 daLogMsg: Found sync point 20 for ROC stream2 Found sync point 20 for ROC stream4 daLogMsg: Found sync point 20 for ROC stream4 socket 21 closed socket 23 closed thread exit for ROC4 thread exit for ROC18 socket 19 closed thread exit for ROC17 socket 22 closed thread exit for ROC14 Found sync point 20 for ROC stream0 daLogMsg: Found sync point 20 for ROC stream0 Found sync point 20 for ROC stream3 daLogMsg: Found sync point 20 for ROC stream3 Resyncronised via control event daLogMsg: Resyncronised via control event got all end events!!!! ROC mask 411672 force_end 3 Segmentation fault (core dumped)



    A copy of this log entry has been emailed to: abbottd@jlab.org,rom@jlab.org