• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name A. Camsonne

    Log entry time 22:25:20 on October 13, 2010

    Entry number 334746

    keyword=coda EB seg faulting at end of run

    Most likely some issues in event synchronization.
    Event builder segfaults at the end of each run, so you need to restart it
    to be able to end/start another run by typing :
    
    coda_eb -n EB2
    
    -------------------
    
    Activating (C)
    daLogMsg: Activating (C)
    Got control event fragments type = 18  node_ix=6
    Build control event: go(stream4, stream0, stream3, stream5, stream1, stream2)
    -- Got all fragments of go
    socket 24 closed
    thread exit for TS11
    Event (Num 128 type 5) NUMBER mismatch -- stream5 (rocid 14) sent -1
    (type 20)
    daLogMsg: Event (Num 128 type 5) NUMBER mismatch -- stream5 (rocid 14)
    sent -1 (type 20)
    Discard data until next control event
    daLogMsg: Discard data until next control event
    Found sync point 20 for ROC stream5
    daLogMsg: Found sync point 20 for ROC stream5
    Found sync point 20 for ROC stream1
    daLogMsg: Found sync point 20 for ROC stream1
    Found sync point 20 for ROC stream2
    daLogMsg: Found sync point 20 for ROC stream2
    Found sync point 20 for ROC stream4
    daLogMsg: Found sync point 20 for ROC stream4
    socket 21 closed
    socket 23 closed
    thread exit for ROC4
    thread exit for ROC18
    socket 19 closed
    thread exit for ROC17
    socket 22 closed
    thread exit for ROC14
    Found sync point 20 for ROC stream0
    daLogMsg: Found sync point 20 for ROC stream0
    Found sync point 20 for ROC stream3
    daLogMsg: Found sync point 20 for ROC stream3
    Resyncronised via control event
    daLogMsg: Resyncronised via control event
    got all end events!!!!
    ROC mask 411672 force_end 3
    Segmentation fault (core dumped)
    
    


    A copy of this log entry has been emailed to: abbottd@jlab.org,rom@jlab.org