User name Magali
Log entry time 12:11:14 on October 21, 2010
Entry number 335960
keyword=Lemo INPUT and OUTPUT of the claorimeter trigger
INPUTS:
LEMO 0 <= External Clock
LEMO 1 <= External Reset
LEMO 2 <= ARS busy come frome the ARS board in the ROC 17
LEMO 3 <= ARS busy come frome the ARS board in the ROC 14
LEMO 4 <= Ts Live
LEMO 5 <= Cosmic
LEMO 6 <= leds pulser clock
LEMO 7 <= S0
LEMO 8 <= S1
LEMO 9 <= S2m
LEMO 10 <= Cer
LEMO 11 <= nothing
OUTPUTS:
LEMO 0 => ARS_STOP = T6
LEMO 1 => ARS_Valid = T5
LEMO 2 => Master or
LEMO 3 => Out master ortrig
LEMO 4 => CLK/n
LEMO 5 => out HRSsingle
LEMO 6 => s2m and cer
LEMO 7 => outscales2m