• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name jroche

    Log entry time 05:22:26 on November 15, 2010

    Entry number 340136

    keyword=Updated epics target readout list

    I noticed that we were not recording enough information about Loop 2. Updated the readings in the Run Start, Run End scripts and the Epics Logger. For example, with the end of run script, this is what we are recording now
    -----
    Target : L2 15 cm
    fan frequency loop 1 : 59.5
    fan frequency loop 2 : 45.5
    fan frequency loop 3 : 0
    Encoder position : 2.38089e+07
    Target type : 2.38089e+07
    temperature loop 1(1) : 22.03
    temperature loop 1(2) : 22.01
    temperature loop 1(3) : 22.29
    Heat exchange loop 1 D2 : 24.5
    temperature loop 2(1) : 19
    temperature loop 2(2) : 95.14
    temperature loop 2(3) : 119.99
    Heat exchange loop 2 LH2 : 19
    temperature loop 3(1) : 0
    temperature loop 3(2) : 0
    temperature loop 3(3) : 0
    Heat exchange loop 3 H2 : 302.1
    pressure loop He : 41.3014
    pressure loop H2 before : 24.3503
    pressure loop H2 return : 23.1495
    pressure loop D2 before : 24.2466
    pressure loop D2 return : 21.8204
    HPH loop 1 : 10.5713
    HPH loop 2 : 39.3654
    HPH loop 3 : 0.00293052
    
    THis is what we recorded before
    Target : L2 15 cm
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 2.38089e+07
    Target type : 2.38089e+07
    temperature loop 1(1) : 22.03
    temperature loop 1(2) : 22
    temperature loop 1(3) : 22.28
    temperature loop 3(1) : 0
    temperature loop 3(2) : 0
    temperature loop 3(3) : 0
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 302.1
    HPH H2 loop 1 : 17.8748
    HPH H2 loop 3 : 0.125618