    keyword=FPP datamap, replay file and onlineGUI UPDATED

    I updated the all FPP related files so that we can replay and show all 4 chambers (front and rear) data now. To be specific,

    * Directory: SRCs/replay (not e07006) 1. db_L.fpp.dat (db file) 2. replay_L.odef (output define file) 3. FPP.cfg (onlineGUI configuration file)

    * If you want to move this to the official shiftworker e07006 directory, you just need to copy (overwrite) db_L.fpp.dat and FPP.cfg to your official directory and copy the corresponding FPP part in the replay_L.odef and paste it into the odef file in e07006 directory.

    The procedure to do the replay is: 0. source SourceThisFirst (to setup the DB directory first) 1. analyzer replay_L.C (or replay_mkj.C) (to generate the rootfile) 2. run online.C("FPP",run number) to open the onlineGUI

    I just analyzer run 1128. Chamber1,2,3 looks okay, but chamber 4 has many missing channels.



    A copy of this log entry has been emailed to: kelleher@jlab.org, jones@jlab.org, pkpan@jlab.org, lselvy@jlab.org