Log entry time 15:59:12 on February 15, 2011
Entry number 347047
keyword=How to Remove EDTM Pulser in Data (BB)
To remove the EDTM pulser from the data for BigBite and HAND, which has
its own source compared to the HRS copies, one needs to place the following
cut:
Ndata.DBB.edtmbb==0
cutting on "Ndata.DBB.edtmbb!=0" will select out the edtm exclusively.
The HRS copies are different and may work differently.