• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 22:13:54 on February 15, 2011

    Entry number 347094

    keyword=End_of_Run_1404
    ****************************
     Run Number: 1404
     End of Run Comment:
    Run_type=Calibration,target_type=LD2 4 cm cell,beam_e0=2.257,beam_raster=on,beam_current=6,leftarm_p=0.899,leftarm_theta=56.0,leftarm_sieve=out,rightarm_p=1.850,rightarm_theta=14.0,rightarm_sieve=out,comment_text=Calibration neutron,bbite_current=518,bbite_theta=97,hand_angle=97,bbite_sieve=out,hand_lead=on
      -- Q1 power trip off in the few 10mins
    
    PRESCALE FACTORS:ps1=100   ps2=1   ps3=10   ps4=1   ps5=1   ps6=0   ps7=0   ps8=0   
    
    EVENTS   : [0]: 21343        [+]: 9983         [-]: 9912         
    TIME     : [0]: 0.627 mins  [+]: 0.452 mins  [-]: 0.452 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  46.12%      [+]:  64.74%      [-]:  64.76%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :T1:473.0/47299.8 Hz   T2[0] :T2:465.5/465.5 Hz   T3[0] :T3:99.0/990.5 Hz   T4[0] :T4: 0.0/0.0  Hz   T5[0] :T5:16.8/16.8 Hz   T6[0] :T6: 0.0/0.0  Hz   T7[0] :T7: 0.0/215441.3 Hz   T8[0] :T8: 0.0/1024.0 Hz   
    T1[+] :T1:472.2/47220.3 Hz   T2[+] :T2:466.2/466.2 Hz   T3[+] :T3:92.7/927.5 Hz   T4[+] :T4: 0.0/0.0  Hz   T5[+] :T5:15.1/15.1 Hz   T6[+] :T6: 0.0/0.0  Hz   T7[+] :T7: 0.0/214978.8 Hz   T8[+] :T8: 0.0/1024.0 Hz   
    T1[-] :T1:472.0/47201.9 Hz   T2[-] :T2:458.9/458.9 Hz   T3[-] :T3:92.8/927.7 Hz   T4[-] :T4: 0.0/0.0  Hz   T5[-] :T5:15.9/15.9 Hz   T6[-] :T6: 0.0/0.0  Hz   T7[-] :T7: 0.0/215113.9 Hz   T8[-] :T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :T1:  17803/1780303  T2[0] :T2:  17520/17520    T3[0] :T3:   3728/37282    T4[0] :T4:      0/0        T5[0] :T5:    631/631      T6[0] :T6:      0/0        T7[0] :T7:      0/8108925  T8[0] :T8:      0/38542    
    T1[+] :T1:  12797/1279790  T2[+] :T2:  12636/12636    T3[+] :T3:   2513/25138    T4[+] :T4:      0/0        T5[+] :T5:    409/409      T6[+] :T6:      0/0        T7[+] :T7:      0/5826472  T8[+] :T8:      0/27753    
    T1[-] :T1:  12793/1279384  T2[-] :T2:  12438/12438    T3[-] :T3:   2514/25144    T4[-] :T4:      0/0        T5[-] :T5:    430/430      T6[-] :T6:      0/0        T7[-] :T7:      0/5830554  T8[-] :T8:      0/27755    
    
    AVERAGE CURRENT
    BCM x1 : 2.5406 uA  BCM x3 : 3.4337 uA  BCM x10: 5.1634 uA  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =       -20.35743 seconds
    
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -603.9 ppm     BCM u3 :   -128.3 ppm     BCM u10:    6.963 ppm     
    BCM d1 :    7.757 ppm     BCM d3 :   -97.55 ppm     BCM d10:   -12.43 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0] : 0.0001272      BCM u3 [0] : 0.0001274      BCM u10[0] : 0.0002572      
    BCM u1 [+] : 9.147E-05      BCM u3 [+] : 9.166E-05      BCM u10[+] : 0.0001851      
    BCM u1 [-] : 9.158E-05      BCM u3 [-] : 9.17E-05       BCM u10[-] : 0.0001851      
    
    BCM d1 [0] : 6.408E-05      BCM d3 [0] : 0.0001311      BCM d10[0] : 0.0001315      
    BCM d1 [+] : 4.612E-05      BCM d3 [+] : 9.435E-05      BCM d10[+] : 9.466E-05      
    BCM d1 [-] : 4.612E-05      BCM d3 [-] : 9.438E-05      BCM d10[-] : 9.467E-05      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1404 at Tue Feb 15 22:13:50 EST 2011
    
    Left Arm Top VDC Current : 5.41992
    Left Arm Bottom VDC Current : 0.146484
    Left Arm Top VDC voltage : 3.99121
    Left Arm Bottom VDC voltage : 4.00391
    -----
    Right Arm Top VDC Current : -5.22461
    Right Arm Bottom VDC Current : -4.63867
    Right Arm Top VDC voltage : 4.00439
    Right Arm Bottom VDC voltage : 3.99414
    -----
    Left Arm Q1 momentum : 0.000866804
    Left Arm Q1 power supply : 0.213626
    Left Arm Q1 gauss meter : 0.0003561
    Left Arm Q2 gauss meter : -0.2039
    Left Arm Q2 power supply current : 387.159
    Left Arm Q2 momentum : 0.899115
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 299.174
    Left Arm D1 momentum : 0.89902
    Left Arm D1 NMR : 0.33287
    Left Arm arm angle : 56.0688
    Left Arm Q3 gauss meter : 0.182169
    Left Arm Q3 power supply current : 357.912
    Left Arm Q3 momentum : 0.899009
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 1.84865
    Right Arm Q1 power supply : 1390.07
    Right Arm Q1 gauss meter : -0.03466
    Right Arm Q2 power supply current : 795.749
    Right Arm Q2 momentum : 1.849
    Right Arm Q2 gauss meter : 0.4164
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 639.862
    Right Arm D1 momentum : 1.84897
    Right Arm D1 NMR : 0.68613
    Right Arm arm angle : -13.999
    Right Arm Q3 power supply current : 735.798
    Right Arm Q3 momentum : 1.84916
    Right Arm Q3 gauss meter : 0.3285
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 518
    BigBite magnet current readback : 517.958
    BigBite Gaussmeter readback : -0.3576
    -----
    Average current of the two cavities : 6.39931
    Current on Unser monitor : 18.8107
    Current on Upstream bcm : 6.4313
    Current on Downstream bcm : 6.36732
    Upstream Cavity Coefficient : 100.8
    Downstream Cavity Coefficient : 83.03
    Current on IBC0L02 (source) : 160.327
    Hall C Current : 150.81
    MBSY1c magnet current (amp) : 94.0754
    MBSY1c Bdl : 564138
    Hall A momentum (Tiefenbach) (HALLA:p) : 5550.5
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 2257.76
    Hall A energy (halla_MeV) : 5550.5
    Hall C energy (hallc_MeV) : 1159.61
    Delta(E)/E width (MV_AI_DXWID) : 4.27649
    IPM1C12.XPOS : -0.054919
    IPM1H04A.XPOS : -1.54377
    IPM1H04A.YPOS : -0.156865
    IPM1H04B.XPOS : -3.49589
    IPM1H04B.YPOS : 2.00887
    -----
    HacL_HPE1313A:0_Ch58 : -0.44043
    HacL_HPE1313A:0_Ch55 : 23.3398
    HacL_HPE1313A:0_Ch54 : -0.39209
    Left Arm Angle Vernier : 43
    Left Arm Scattering Angle : 56.0688
    Left VDC -DISC LVL Top : 3.90576
    Left VDC -DISC LVL Bottom : 3.96338
    Left VDC -DISC LVL Voltage1 : 4.97217
    Left VDC -DISC LVL Voltage2 : -5.05811
    -----
    Right Arm Collimator : -0.00180664
    HacR_HPE1313A:0_Ch58 : -0.708984
    HacR_HPE1313A:0_Ch55 : 22.3633
    HacR_HPE1313A:0_Ch54 : -1.04541
    Right Arm Angle Floor Angle : -14
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : -13.999
    -----
    Target OTR x-position : 0
    Target OTR y-position : 0
    Target OTR x-width : 0
    Target OTR y-width : 0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out