• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name V. Sulkosky

    Log entry time 01:50:03 on February18,2011

    Entry number 347446

    keyword=Scope for Final Setting

    Fig. 1 shows the scope traces for the final setting for D-threshold.
    We are currently running elastic e'p, which has the fastest particle
    for this experiment (968 MeV/c) versus the deuteron (900 MeV/c) and
    threshold proton at (490 MeV/c).

    I set the delay for T1 such that the retiming on the HRS's was still
    fine, though the right arm is very tight. From the elastic proton,
    setting the deuteron will shift the coincidence by about 68 ns. I
    attempted to balance this change so that when T3 shifts to the right,
    T1 will still define the time for T5. This resulted in the following
    setting for T1:

    ./t1_delay 76 0


    FIGURE 1