User name V. Sulkosky
Log entry time 11:26:17 on February 20, 2011
Entry number 347797
This entry is a followup to: 347471
keyword=Configuration Change Consequences
Unfortunately, I did not catch the ramifications of removing ROC 10 out of
the readout until this morning. I apologize about that. ROC 10 contains
the TDC for the trigger bit and latch patterns from the trigger supervisor.
That means you cannot use the evtypebits variable to cut on event type.
The trigger supervisor itself does label each event with an event type.
This is incorporated into the analyzer as Event_Branch.fEvtHdr.fEvtType .
However this variable ignores correlations between different event types
for the same event. Hence you only know which event type came first and
not what other event types were present at the TS.
Also the raw coincidence time variable is now gone: DBB.t3, since ROC 10 is
not read out. But thankfully there is a copy on the left arm that I will
implement.