I went into the hall to adjust the lead flows on the Right Dipole. The "Lead A Voltage" was reading around 6.5V and the "Lead B Voltage" was reading around 3.4V. Noting the different readbacks of the lead flows, I thought I might try increasing the flow on the lead with the 6.5V. I found both flows on the visual gauges right about where I had set them, with the tops just at about 30. I increased the flow of the visual gauge labeled for the A lead, to about 35. The "Lead B Voltage" decreased. I set the flow back to 30 and the "Lead B Voltage" increased. I increased the flow of the visual gauge labeled for the B lead, to between 35 and 40. The "Lead A Voltage" decreased to about 6.3V. I left it there.