    keyword=Re-enabled EDTM on left and right arms

    I re-enabled the EDTM system with
    
    ./edtmsetup 0 92 232
    
    where the first parameter is the left HRS edtm delay should be zero unless
    left HRS is detecting a proton.  The second parameter is the right HRS edtm
    delay, which normally is 92 if S2m is in both T1 and T3.   If the right 
    HRS detects protons, then it can be higher.  The last parameter sets the 
    relative delay between BB/HAND and the HRS edtms.  This number is actually 
    in units of 2.2 ns and is normally around 220 and 230.  The maximum this 
    number can be is about 250 (550 ns).  The relative delay between HRS and 
    BB is large due to the long cables to carry the signals from the PMTs to 
    the weldment at which the EDTM is injected.
    