    keyword=Deadtime for kinematic 1

    Summary of deadtime measurements for N-Delta kinematic 1:

    Run    Current [uA]      Deadtime [%]   T5 rate [kHz]    Comments
    +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
    2055      45                 61             4.6           Threearm
    2056      31                 44             2.1           Threearm
    2057      20.5               25             0.98          Threearm
    2058      19.8               21             0.91          dThresh2arm
    2059      15                 15             0.55          dThresh2arm
    
    To get reasonable deadtime ~ 15%, we dropped the BB/HAND crates and went
    to the 'dThresh2arm' configuration. That only improved the deadtime by
    about 20% (4% absolute). We then lowered the current to 15 uA. We
    might be able to double the current if we buffer the DAQ. That will probably
    require a few hours of work in the hall to gather the busy signals.

    A copy of this log entry has been emailed to: kalyan,doug,danez,sparveri