• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name V. Sulkosky

    Log entry time 12:00:40 on March 01, 2011

    Entry number 349357

    This entry is a followup to: 349353

    keyword=Busy Signals Gathered at weldment

    The busy signals have been gathered from the left and right HRS and ROC 10 
    at the weldment and "OR"ed together.  I then connected the "OR" of busies
    to the FB input on the TS2 module.  The hardware is now in place to run
    in buffered mode.  Now we just need to test it.
    
    btw, I checked the widths on all the busy signals:
    
    left arm:  8.5 microseconds
    right arm: 11 microseconds
    ROC 10:    2.3 microseconds
    bbts1:     upto 5 milliseconds!
    
    Hence the trigger supervisor is for some reason causing a lot of deadtime.
    Need to investigate.
    


    A copy of this log entry has been emailed to: kalyan,rom,camsonne,lselvy,danez