    keyword=Trigger timing

    Changes to the CRL code for ROCs 1,2,3,and 4 were made adding calls to getSCALER(0) such that the timing of each trigger could be determined.

    The start variable comes 1 word after the header 0xdeaddead, the stop word is two words after this header.

    The dec data class db_DBB.dat has been updated with:
    #Deadtime Calculations
    R1start word 1 0xdeaddead 1
    R1stop word 1 0xdeaddead 2
    R2start word 1 0xdeaddead 1
    R2stop word 1 0xdeaddead 2
    R3start word 1 0xdeaddead 1
    R3stop word 1 0xdeaddead 2
    R4start word 1 0xdeaddead 1
    R4stop word 1 0xdeaddead 2