    User name V. Sulkosky

    Log entry time 09:43:52 on March 03, 2011

    Entry number 349826

    keyword=Trigger supervisor deadtime

    Steve Wood checked the forced deadtimes in the TS crl code. It should be set to 20 microseconds. I then suggested I run this at the bbts1 component winodw:

    -> tsTimerStatus()

    *** Trigger Supervisor Timers ***

    Level 2 : Enabled = 200 ns Level 3 : Enabled = 200 ns Front-End Busy : Enabled = 20000 ns Clear Permit : Disabled = 0 ns Clear Hold : Disabled = 0 ns value = 42 = 0x2a = '*'

    Looks like the frontend busy on bbts1 is only 20 microseconds as expected.



    A copy of this log entry has been emailed to: saw,rom,camsonne,lselvy