I added code into the ROC crl code such that we can produce the readout time for ROC10. The old crl code can be found at bb_sfi1.crl.3Mar2011.
This is the same setup as the other, time stamp at the beginning of davetrig and one at the end. The readout time is the difference of these.
The db_DBB.dat (Dec Data Class) has also been updated to show this.
I am still having issues with the bbts1 code as I can't seem to find the fast clock. The code is there is someone knows which channel and slot it is in.