• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name R. Michaels

    Log entry time 08:29:12 on March 4,2011

    Entry number 350012

    Followups:

    keyword=download loose triggers, deadtime check

    I downloaded a "loose" trigger (mlu2_loose.data) for T2, T4
    to make a higher rate. Vince turned on HAND temporarily.
    The rates are
    T1 = 12 Hz (normal)
    T2 = 2.2 kHz
    T3 = 16 Hz (normal)
    T4 = 720 Hz
    T6 = 6 Hz
    T7 = 800 Hz (HAND)

    Will run like this for deadtime checks. Don't forget to switch
    back. Also, I found a problem: It seems that T4 is coming from
    output 1 or 3, so I needed mlu2_loose2.data. This could mean
    the cabling is wrong for T4. I'll check when I climb up there.