Please keep track of the coulomb count for the good runs and record it in the shift summary! This is what we would like to use to determine when we will change kinematic settings. Ole made a nice script to count the amount of charge from the run ends, given a range of runs. It looks for "Production" and "LH2" runs.
Make sure the 3rd person replays the data and looks at the online GUI and the ndelta plots.
The plan for overnight is:
* Collect 1418 mC at kinematic setting #11 in the run plan. We are using the 4cm LH2 target at 55 uA. Make sure to do a 1hr Al run and a 5 min BeO run in the middle of the setting.
* Go to kinematic setting #12 by moving the LHRS to 48 degrees. The RHRS doesn't change. We are using the 4cm LH2 target, and would like to use 80 uA.
* Check the signal-to-noise in the standard plots (instructions posted near adaql2) and adjust the prescales to get the rates posted on the white board. Post the plots. It may be necessary to use a lower beam current, but not likely.
* Collect 1418 mC at kinematic setting #12. Make sure to do a 1hr Al run and a 5 min BeO run in the middle of the setting. This should take until sometime Sunday day shift, in the morning.
Please don't hesitate to call the RC phone if you have any questions.