Using run#2254
The current and the BCM scaler has the following relation:
I_a = [N_a/t - offset_a]/const_K_a
where I_a is the current
N_a/t = scaler rate (Hz)
off_set_a = off_set
a = 1,3,10 is the gain factor
we have:
bcm constK Offset constK_err offset_err
bcm_u1 2059.225227 627.980503 0.317307 10.325868
bcm_u3 6385.086733 259.501488 0.317307 10.325868
bcm_u10 19352.327633 627.422835 1.358402 12.284888
bcm_d1 1234.216156 154.756427 0.317307 10.325868
bcm_d3 7635.017957 636.693049 0.317307 10.325868
bcm_d10 24207.080456 686.709379 1.358402 12.284888
upstream: k10/k1 = 9.397868
upstream: k3/k1 = 3.100723
downstream: k10/k1 = 19.613323
downstream: k3/k1 = 6.186127
The downstream seem to be double the rate.
k1_u/k1_d = 1.668448
k3_u/k3_d = 0.836290
k10_u/k10_d = 0.799449
Figure 1