Log entry time 17:58:30 on March 9,2011
Entry number 351161
This entry is a followup to: 351094
Followups:
keyword=Chamber 1, problem?
Weird data for BigBite for cosmic run # 2655.
Two plots below show hit wire distribution for the chamber 1.
In the first plot I ploted "BB.mwdc.[plane].hit.wire" without index.
In the second plot I did the same, however I added additional index to the variable in order to look on the first hit, so "BB.mwdc.[plane].hit.wire[0]".
In the second case I see number of "noisy" channels. ALL these channels correspond to the ROC 10 slot 1.
If I look on the next hits I don't see this "noise". However my statistics for the next hits is very low.
Chamber 2 is behaving normaly as I will expect from cosmic.
FIGURE 1
FIGURE 2