NEXT
Make New Entry,
Make Followup Entry
User name A. Camsonne
Log entry time 01:34:35 on March 19, 2011
Entry number 352500
keyword=Additionnal channels in TDCs
I made a copy of L1A and T3 using a VME NIM/ECL converter for the VME
boards. L1A goes to channel 0 and T3 goes to channel 1 of this module.
I updated the DBB database to look at those
For the F1 :
# F1TDC Additionnal signal
f1T3 crate 5 15 52
f1L1A crate 5 15 53
the signal have two empty channels between them and the reference channel.
For 1190 :
ref1 crate 5 12 119
1190L1A crate 5 12 120
ref3 crate 5 12 121
1190T3 crate 5 12 122
For TDC in slot 23 ROC10
l1a_b crate 10 23 54
the L1A seems to have been already plugged
l1a crate 10 23 40
those are on 6th channel of level translator ( starting at 0 ) on group
starting by 48 and 64, so that would be 53 and 69
A copy of this log entry has been emailed to: doug,brads,kelleher,eip,rshneor,orchen,igorko,rom,saw,lselvy,danez,nmuangma