NEXT
Make New Entry,
Make Followup Entry
User name V. Sulkosky
Log entry time 23:27:03 on March 29, 2011
Entry number 353663
keyword=Updated DBB database file
Today I updated the DBB database file to include the replay of the BB
scaler channel for the EDTM signal. The DB directories affected are
20110324 and 20110326 with the following lines added:
# BB EDTM Scaler
scl1a word 29 bbe00000 10
scedtmbb word 29 bbe00000 11
scfclk word 29 bbe00000 12
The header bbe00000 represents the first scale module in bbts1. Word
10 the scaler copy of L1A, word 11 is the BB EDTM copy and the twelfth
word is the fast clock.
The DBB class fills the variable for each event, but the scalers are only
readout every 100 events. Hence not every event has a new scaler
reading.
A copy of this log entry has been emailed to: igoko,orchen,nmuangma,yez