• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name V. Sulkosky

    Log entry time 23:27:03 on March 29, 2011

    Entry number 353663

    keyword=Updated DBB database file

    Today I updated the DBB database file to include the replay of the BB 
    scaler channel for the EDTM signal.  The DB directories affected are
    20110324 and 20110326 with the following lines added:
    
    # BB EDTM Scaler
    scl1a       word     29    bbe00000   10
    scedtmbb    word     29    bbe00000   11
    scfclk      word     29    bbe00000   12
    
    The header bbe00000 represents the first scale module in bbts1.  Word
    10 the scaler copy of L1A, word 11 is the BB EDTM copy and the twelfth 
    word is the fast clock.
    
    The DBB class fills the variable for each event, but the scalers are only
    readout every 100 events.  Hence not every event has a new scaler 
    reading.
    


    A copy of this log entry has been emailed to: igoko,orchen,nmuangma,yez