    User name V. Sulkosky

    Log entry time 14:22:55 on April 21, 2011

    Entry number 356372

    keyword=Trigger Inputs to R-HRS Scalers

    I added the left HRS triggers to the right arm scalers.  I sent T3 and T7
    to the right HRS via the green and blue RG-58 cables that were spares.  
    I then moved the T1 (S1&S2) input to the T6 input and connected the 3-of-3
    trigger to T1.  I also connected T3 and T7 to the third and seventh inputs
    to the scaler.  Here T3 is the 3-of-3 trigger and T7 is S1&&S2.
    
    Zhihong was going to send a copy of T4 from the left arm to the right arm,
    since I did not have any additional cables to send T4 from the weldment.
    
    The xscaler displays for the left and right arm are consistent for all the
    different triggers.
    


    A copy of this log entry has been emailed to: yez,camsonne,doug,solvigno,narbe,johna