• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name igorko

    Log entry time 01:56:20 on May 11, 2011

    Entry number 358898

    Followups:

    keyword=doubles for Slanted Carbon

    I compared the double coincidence runs for Slanted Carbon.
    
    We expect to have same condition. I compared two runs 3168 30 uA and new
    run 4364, 30 uA.
    
    I normalized the new data to have the same charge.
    I see that we didn't get the same results for Recoils
    
    below I attach table for number of events:
    
    ================== 3168     ==========================
                    Charge =        0.1008
     Signal + BG,   BB = 3930
     Signal,        BB = 846
     BG,            BB = 3084
    
     Signal + BG,  HAND (charged) = 170513
     Signal,       HAND (charged) = 4410.5
     BG,           HAND (charged) = 166102
    
     Signal + BG,  HAND (neutral) = 105113
     Signal,       HAND (neutral) = 1772
     BG,           HAND (neutral) = 103341
    
    ===========================================================
    ==================   4364   ================================
                    Charge =        0.1163
     Signal + BG,   BB = 2494.43
     Signal,        BB = 543.436
     BG,            BB = 1951
    
     Signal + BG,  HAND (charged) = 102291
     Signal,       HAND (charged) = 1635.07
     BG,           HAND (charged) = 100656
    
     Signal + BG,  HAND (neutral) = 64450.5
     Signal,       HAND (neutral) = 956.429
     BG,           HAND (neutral) = 63494
    
    ===========================================================
    
    


    A copy of this log entry has been emailed to: eip,doug,sgilad@mit.edu,rshneor,orchen,vasulk,eip@tauphy.tau.ac.il



    Figure 1