    User name a-onl

    Log entry time 13:33:35 on September 26, 2011

    Entry number 359259

    keyword=Start_Run_20139,Run_type=Cosmics,target_type=No Target, Empty,beam_e0=1.162,beam_raster=off,beam_current=0,leftarm_p=1,leftarm_theta=5.0,leftarm_sieve=out,rightarm_p=0,rightarm_theta=5.0,rightarm_sieve=out,comment_text=T8 test
    Run Timestamp:       Mon Sep 26 13:32:33 EDT 2011
    Beginning-of-run EPICS data for Run Number 20139 at Mon Sep 26 13:32:42 EDT 2011
    
    
    
    Run_type=Cosmics
    target_type=No Target, Empty
    beam_e0=1.162
    beam_raster=off
    beam_current=0
    leftarm_p=1
    leftarm_theta=5.0
    leftarm_sieve=out
    rightarm_p=0
    rightarm_theta=5.0
    rightarm_sieve=out
    comment_text=T8 test
    
    
    ; RHRS DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
    ; PS factor of zero DISABLES the trigger.
    ; This means T9 - T12 are disabled unless you have a PS factor >0
    ; (however, T9 - T12 cannot actually be prescaled, only disabled/enabled) 
    ; T1 = R-HRS T1 trigger
    ; T2 = R-HRS T2 trigger 
    ; (to be changed later ...0
    ; T8 = 1024 Hz pulser
    ; String should be one line, no spaces, ending in carriage return
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    
    ps1=1,ps2=0,ps3=0,ps4=0,ps5=0,ps6=0,ps7=0,ps8=0,ps9=0
    
    
    
    
    -----
    Right Arm Q1 momentum : 0.00334571
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -6.44e-05
    Right Arm Q2 power supply current : -0.000112989
    Right Arm Q2 momentum : 0.00170998
    Right Arm Q2 gauss meter : -0.0004068
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : -0.0297142
    Right Arm D1 momentum : 0.0035023
    Right Arm D1 NMR : 0.0659463
    Right Arm Q3 power supply current : -8.36673e-06
    Right Arm Q3 momentum : -2.10268e-08
    Right Arm Q3 gauss meter : -0.0007526
    Right Arm Q3 power supply polarity : enabled
    Right Arm B Field Hall Probe (D-G) : 0.0012572
    -----
    Right Arm Top VDC Current : -1.75781
    Right Arm Bottom VDC Current : -1.70898
    Right Arm Top VDC voltage : -0.0166016
    Right Arm Bottom VDC voltage : -0.0253906
    -----
    Right Arm Arm Collimator : -0.00170898
    HacR_HPE1313A:0_Ch58 : -0.700195
    HacR_HPE1313A:0_Ch55 : 22.2656
    HacR_HPE1313A:0_Ch54 : -1.03418
    Right Arm Angle Floor Angle : 12.5
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 12.697
    ----
    SLI data valid? : slia:DataValid --- Invalid channel name
    SLI horiz size mm : slia:MV_AO_DYWIDS --- Invalid channel name
    SLI Energy spread *10^5 : slia:MV_AO_SPREADS --- Invalid channel name
    SLI x position : slia:MV_AI_DYPOS --- Invalid channel name
    SLI vert. size mm : slia:MV_AO_DXWIDS --- Invalid channel name
    SLI y position : slia:MV_AI_DXPOS --- Invalid channel name
    -----