• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name Melissa

    Log entry time 11:30:34 on November 07, 2011

    Entry number 359324

    keyword=ROC5 Errors

    This morning Ryan and I tried to troubleshoot the problems in ROC5.  We
    replaced the GAC card with one from BigBite and set the address. We ran
    the two testcodes for the ADC and TDC in ROC5 and got the following errors:
    
    -> test_1877(23)
    resetRegisterGroupLca2 = FAE0201C
    FastbusTimeoutRegister = FAE02000
    FastbusdArbitrationLevelReg = FAE02004
    fastPrimDsr = FAE10004
    Block Read data stored at address 0x1ebf96a0 dmaptr = 0x26bf96a0
    ERROR: Read Module ID
    0x1ebfb190 (tShell): SFI_ADR_ERR: Fastbus Arbitration timeout 
    0x1ebfb190 (tShell): ** Resetting Sequencer ** 
    value = 32 = 0x20 = ' '
    
    
    -> test_1881(24)
    resetRegisterGroupLca2 = FAE0201C
    FastbusTimeoutRegister = FAE02000
    FastbusdArbitrationLevelReg = FAE02004
    fastPrimDsr = FAE10004
    Block Read data stored at address 0x1ebfad90 ,dmaptr = 0x26bfad90
    Block Read Mode: 32 bit Block I/O
    ERROR: Read Module ID  res=0x1c020
    value = 35 = 0x23 = '#'
    
    We also tried reseating the cards, but still came up with the same errors.
    
    
    
    
    
    
    


    A copy of this log entry has been emailed to: vasulk@jlab.org, camsonne@jlab.org, rbzie@jlab.org, melissac@jlab.org