• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 12:33:53 on December 5, 2011

    Entry number 359570

    keyword=Start_Run_1536,Run_type=Cosmics,target_type=No Target, Empty,beam_e0=4.456,beam_raster=off,beam_current=,leftarm_p=3.6104,leftarm_theta=20.3,leftarm_sieve=out,rightarm_p=1.3825,rightarm_theta=33.5,rightarm_sieve=out,comment_text=DAQ tests
    Beginning-of-run EPICS data for Run Number 1536 at Mon Dec 5 12:33:01 EST 2011
    
    
    
    Run_type=Cosmics
    target_type=No Target, Empty
    beam_e0=4.456
    beam_raster=off
    beam_current=
    leftarm_p=3.6104
    leftarm_theta=20.3
    leftarm_sieve=out
    rightarm_p=1.3825
    rightarm_theta=33.5
    rightarm_sieve=out
    comment_text=DAQ tests
    
    
    ; LHRS DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
    ; PS factor of zero DISABLES the trigger.
    ; This means T9 - T12 are disabled unless you have a PS factor >0
    ; (however, T9 - T12 cannot actually be prescaled, only disabled/enabled) 
    ; T1 = R-HRS T1 trigger
    ; T2 = R-HRS T2 trigger 
    ; (to be changed later ...0
    ; T8 = 1024 Hz pulser
    ; String should be one line, no spaces, ending in carriage return
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    
    ps1=0,ps2=0,ps3=1,ps4=0,ps5=0,ps6=0,ps7=0,ps8=0,ps9=0
    
    
    
    Left septum set current : MSEPLRSETI --- Invalid channel name
    Left septum current readback : MSEPLMIR --- Invalid channel name
    Left septum upper coil T : MSEPLUPCOILT --- Invalid channel name
    Left septum lower coil T : MSEPLLOWCOILT --- Invalid channel name
    Right septum set current : MSEPRRSETI --- Invalid channel name
    Right septum current readback : MSEPRMIR --- Invalid channel name
    Right septum upper coil T : MSEPRUPCOILT --- Invalid channel name
    Right septum lower coil T : MSEPRLOWCOILT --- Invalid channel name
    Left septum yoke T : MSEPLT2R --- Invalid channel name
    Left septum bore shield T : MSEPLT5R --- Invalid channel name
    Left Arm Q1 momentum : 0.000926259
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0002352
    Left Arm Q2 power supply current : -0.000303248
    Left Arm Q2 momentum : -7.04244e-07
    Left Arm Q2 gauss meter : -0.0007942
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 0.0833422
    Left Arm D1 momentum : 0.00327979
    Left Arm D1 NMR : 0.32892
    Left Arm Q3 power supply current : -0.00046267
    Left Arm Q3 momentum : -1.20938e-06
    Left Arm Q3 gauss meter : 0.00155329
    Left Arm Q3 power supply polarity : enabled
    Left Arm B Field Hall Probe (D-G) : -0.0011782
    -----
    Left Arm Top VDC Current : 0.488281
    Left Arm Bottom VDC Current : -22.3633
    Left Arm Top VDC voltage : 4.00684
    Left Arm Bottom VDC voltage : 3.99756
    -----
    HacL_HPE1313A:0_Ch58 : -0.300293
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : -0.0131836
    Left Arm Angle Floor Angle : 0
    Left Arm Angle Vernier : 0
    Left Arm Scattering Angle : -0.179
    -----
    Right Arm D1 momentum : 0.0130216
    Right Arm arm angle : 0.197
    -----
    Left VDC -DISC LVL Top : 3.9043
    Left VDC -DISC LVL Bottom : 3.95898
    Left VDC -DISC LVL Voltage1 : 4.96436
    Left VDC -DISC LVL Voltage2 : -5.05273
    Left VDC -DISC LVL Top Set : 4
    Left VDC -DISC LVL Bottom Set : 4