NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 11:11:19 on December 7, 2011
Entry number 359614
keyword=Start_Run_1559,Run_type=Cosmics,target_type=empty,beam_e0=4.456,beam_raster=off,beam_current=,leftarm_p=3.6104,leftarm_theta=20.3,leftarm_sieve=out,septum_current=,comment_text=DAQ tests
Beginning-of-run EPICS data for Run Number 1559 at Wed Dec 7 11:10:35 EST 2011
Run_type=Cosmics
target_type=empty
beam_e0=4.456
beam_raster=off
beam_current=
leftarm_p=3.6104
leftarm_theta=20.3
leftarm_sieve=out
septum_current=
comment_text=DAQ tests
; LHRS DAQ on adaql2/a-onl account
; Prescale factors (integer), downloaded each run at prestart.
; Change this file only in-between runs.
; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
; PS factor of zero DISABLES the trigger.
; This means T9 - T12 are disabled unless you have a PS factor >0
; (however, T9 - T12 cannot actually be prescaled, only disabled/enabled)
; T1 = R-HRS T1 trigger
; T2 = R-HRS T2 trigger
; (to be changed later ...0
; T8 = 1024 Hz pulser
; String should be one line, no spaces, ending in carriage return
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
ps1=0,ps2=0,ps3=1,ps4=0,ps5=0,ps6=0,ps7=0,ps8=0,ps9=0
Left Arm Q1 momentum : 0.000364558
Left Arm Q1 power supply : 0
Left Arm Q1 gauss meter : 0.0002857
Left Arm Q2 power supply current : -0.000224628
Left Arm Q2 momentum : -9.56381e-07
Left Arm Q2 gauss meter : -0.0008267
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 0.0795604
Left Arm D1 momentum : 0.00343123
Left Arm D1 NMR : 0.328303
Left Arm Q3 power supply current : -0.000846347
Left Arm Q3 momentum : -1.644e-06
Left Arm Q3 gauss meter : 0.00154885
Left Arm Q3 power supply polarity : enabled
Left Arm B Field Hall Probe (D-G) : -0.0012326
-----
Right Arm Q1 momentum : 0.0030965
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -7.84e-05
Right Arm Q2 power supply current : 0.000169378
Right Arm Q2 momentum : 0.00397861
Right Arm Q2 gauss meter : -0.0009202
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.000190625
Right Arm D1 momentum : 0.00575859
Right Arm D1 NMR : 0.342263
Right Arm Q3 power supply current : 0.000104617
Right Arm Q3 momentum : 0.0072568
Right Arm Q3 gauss meter : -0.0015965
Right Arm Q3 power supply polarity : enabled
Right Arm B Field Hall Probe (D-G) : -0.002113
-----
Left Arm Top VDC Current : -0.830078
Left Arm Bottom VDC Current : 23.9746
Left Arm Top VDC voltage : 4.00537
Left Arm Bottom VDC voltage : 3.99805
-----
Right Arm Top VDC Current : 1.31836
Right Arm Bottom VDC Current : -3.56445
Right Arm Top VDC voltage : 4.00977
Right Arm Bottom VDC voltage : 4.00977
-----
HacL_HPE1313A:0_Ch58 : -0.300293
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : -0.0126953
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 12.4997
-----
Right Arm D1 momentum : 0.00575859
Right Arm arm angle : 12.501
-----
Left VDC -DISC LVL Top : 3.90479
Left VDC -DISC LVL Bottom : 3.9585
Left VDC -DISC LVL Voltage1 : 4.96533
Left VDC -DISC LVL Voltage2 : -5.05322
Left VDC -DISC LVL Top Set : 4
Left VDC -DISC LVL Bottom Set : 4
-----
HacR_HPE1313A:0_Ch58 : -0.692871
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -1.03174
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.501
-----
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : IPM1H04A.XPOS --- Invalid channel name
IPM1H04A.YPOS : IPM1H04A.YPOS --- Invalid channel name
IPM1H04B.XPOS : IPM1H04B.XPOS --- Invalid channel name
IPM1H04B.YPOS : IPM1H04B.YPOS --- Invalid channel name
Survey X offset bpmA : IPM1H04A.XSOF --- Invalid channel name
Survey Y offset bpmA : IPM1H04A.YSOF --- Invalid channel name
Survey X offset bpmB : IPM1H04B.XSOF --- Invalid channel name
Survey Y offset bpmB : IPM1H04B.YSOF --- Invalid channel name
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2626.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 88.1719
Wien BDL (First Solenoid) (Gcm) : 978.6
Wien BDL (Second Solenoid) (Gcm) : 978.6
Wien angle (Horizontal) : 0
Wien BDL (Gcm) : -25
Wien HV Polarity (Horizontal) : POSITIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 7.0175
Laser power Hall A : 0
Half-wave plate (off=out) : IN
rotating waveplate : 6479.1
Beam Half-wave plate (off=out) : IN
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015