NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 08:32:34 on December 16, 2011
Entry number 360146
keyword=Start_Run_1766,Run_type=Commission,target_type=Carbon,beam_e0=1.7,beam_fraster=off,beam_sraster=off,beam_current=0,leftarm_p=1.7,leftarm_theta=12.5,leftarm_sieve=out,septum_current=460,comment_text=bpm check, bpm check 0 0 on 1H05B
Beginning-of-run EPICS data for Run Number 1766 at Fri Dec 16 08:32:30 EST 2011
Run_type=Commission
target_type=Carbon
beam_e0=1.7
beam_fraster=off
beam_sraster=off
beam_current=0
leftarm_p=1.7
leftarm_theta=12.5
leftarm_sieve=out
septum_current=460
comment_text=bpm check, bpm check 0 0 on 1H05B
;This file is automatically generated from Prescales GUI.
;To generate this file, type "prescaleL" without quotes on a-onl@adaql2
;terminal then input the desired prescales and Save.
;T3 = L-arm scint trig (s1.AND.s2m)
;T4 = L-arm efficiency trigger
;T8 = 1024 Hz pulser or whatever
ps1=0,ps2=0,ps3=2,ps4=1,ps5=0,ps6=0,ps7=0,ps8=0
Left Arm Q1 momentum : 1.13332
Left Arm Q1 power supply : 852.636
Left Arm Q1 gauss meter : -0.07086
Left Arm Q2 power supply current : 702.772
Left Arm Q2 momentum : 1.63208
Left Arm Q2 gauss meter : 0.3711
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 582.582
Left Arm D1 momentum : 1.73721
Left Arm D1 NMR : 0.642887
Left Arm Q3 power supply current : 691.01
Left Arm Q3 momentum : 1.73569
Left Arm Q3 gauss meter : -0.34795
Left Arm Q3 power supply polarity : disabled
Left Arm B Field Hall Probe (D-G) : -0.6185
-----
Right Arm Q1 momentum : 1.57006
Right Arm Q1 power supply : 859.739
Right Arm Q1 gauss meter : -0.021532
Right Arm Q2 power supply current : 1397.19
Right Arm Q2 momentum : 3.20487
Right Arm Q2 gauss meter : 0.4894
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 534.381
Right Arm D1 momentum : 1.55598
Right Arm D1 NMR : 0.577407
Right Arm Q3 power supply current : 1096.09
Right Arm Q3 momentum : 2.03182
Right Arm Q3 gauss meter : 0.7291
Right Arm Q3 power supply polarity : disabled
Right Arm B Field Hall Probe (D-G) : -0.5696
-----
Left Arm Top VDC Current : 1.31836
Left Arm Bottom VDC Current : 21.6309
Left Arm Top VDC voltage : 4.0083
Left Arm Bottom VDC voltage : 3.99854
-----
Right Arm Top VDC Current : 0.488281
Right Arm Bottom VDC Current : 0.439453
Right Arm Top VDC voltage : 4.01562
Right Arm Bottom VDC voltage : 3.97266
-----
HacL_HPE1313A:0_Ch58 : -0.299316
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : -0.0219727
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm D1 momentum : 1.55598
Right Arm arm angle : 12.501
-----
Left VDC -DISC LVL Top : 3.90674
Left VDC -DISC LVL Bottom : 3.96191
Left VDC -DISC LVL Voltage1 : 4.96826
Left VDC -DISC LVL Voltage2 : -5.0625
Left VDC -DISC LVL Top Set : 4
Left VDC -DISC LVL Bottom Set : 4
-----
HacR_HPE1313A:0_Ch58 : -0.697754
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -1.02588
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.501
-----
IPM1C12.XPOS : -1.03588
IPM1C12.YPOS : 0.692724
IPM1H05A.XPOS : -0.40002
IPM1H05A.YPOS : 0.262822
IPM1H05B.XPOS : -0.130126
IPM1H05B.YPOS : 0.109198
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2626.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : -92.0371
Wien BDL (First Solenoid) (Gcm) : -1021.5
Wien BDL (Second Solenoid) (Gcm) : -1021.5
Wien angle (Horizontal) : 0
Wien BDL (Gcm) : -25
Wien HV Polarity (Horizontal) : POSITIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 152
Laser power Hall A : 0
Half-wave plate (off=out) : IN
rotating waveplate : 6478
Beam Half-wave plate (off=out) : IN
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Right septum current : 480.964
Left septum current : 460.263
Target In : disabled
Target Out : enabled
Helium Pressure : disabled