NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 21:29:46 on December 16, 2011
Entry number 360244
keyword=Start_Run_20950,Run_type=Production,target_type=empty,beam_e0=1.72,beam_fraster=off,beam_sraster=off,beam_current=1,rightarm_p=1.72,rightarm_theta=5.69,rightarm_sieve=out,septum_current=481,comment_text=BCM Test
Run Timestamp: Fri Dec 16 21:29:28 EST 2011
Beginning-of-run EPICS data for Run Number 20950 at Fri Dec 16 21:29:41 EST 2011
Run_type=Production
target_type=empty
beam_e0=1.72
beam_fraster=off
beam_sraster=off
beam_current=1
rightarm_p=1.72
rightarm_theta=5.69
rightarm_sieve=out
septum_current=481
comment_text=BCM Test
;This file is automatically generated from Prescales GUI.
;To generate this file, type "prescaleL" without quotes on a-onl@adaql2
;terminal then input the desired prescales and Save.
;T1 = R-arm scint trig (s1.AND.s2m)
;T2 = R-arm efficiency trigger
;T8 = 1024 Hz pulser or whatever
ps1=3,ps2=1,ps3=0,ps4=0,ps5=0,ps6=0,ps7=0,ps8=0
Left Arm Q1 momentum : 1.025
Left Arm Q1 power supply : 771.138
Left Arm Q1 gauss meter : -0.06412
Left Arm Q2 power supply current : 632.968
Left Arm Q2 momentum : 1.46997
Left Arm Q2 gauss meter : 0.3344
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 519.114
Left Arm D1 momentum : 1.55596
Left Arm D1 NMR : 0.57586
Left Arm Q3 power supply current : 748.587
Left Arm Q3 momentum : 1.88031
Left Arm Q3 gauss meter : -0.37718
Left Arm Q3 power supply polarity : disabled
Left Arm B Field Hall Probe (D-G) : -0.5541
-----
Right Arm Q1 momentum : 1.57006
Right Arm Q1 power supply : 859.739
Right Arm Q1 gauss meter : -0.021512
Right Arm Q2 power supply current : 701.287
Right Arm Q2 momentum : 1.60861
Right Arm Q2 gauss meter : 0.3685
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 593.641
Right Arm D1 momentum : 1.72002
Right Arm D1 NMR : 0.638278
Right Arm Q3 power supply current : 825.389
Right Arm Q3 momentum : 1.53002
Right Arm Q3 gauss meter : 0.3666
Right Arm Q3 power supply polarity : disabled
Right Arm B Field Hall Probe (D-G) : -0.6296
-----
Left Arm Top VDC Current : -0.78125
Left Arm Bottom VDC Current : -19.0918
Left Arm Top VDC voltage : 4.00879
Left Arm Bottom VDC voltage : 3.99902
-----
Right Arm Top VDC Current : -1.80664
Right Arm Bottom VDC Current : -2.14844
Right Arm Top VDC voltage : 4.01758
Right Arm Bottom VDC voltage : 3.97314
-----
HacL_HPE1313A:0_Ch58 : -0.29834
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : -0.0209961
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm D1 momentum : 1.72002
Right Arm arm angle : 12.501
-----
Left VDC -DISC LVL Top : 3.90479
Left VDC -DISC LVL Bottom : 3.95996
Left VDC -DISC LVL Voltage1 : 4.96729
Left VDC -DISC LVL Voltage2 : -5.06299
Left VDC -DISC LVL Top Set : 4
Left VDC -DISC LVL Bottom Set : 4
-----
Right Arm Arm Collimator : 0.0632324
HacR_HPE1313A:0_Ch58 : -0.697266
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -1.02539
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.501
-----
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H05A.XPOS : 0
IPM1H05A.YPOS : 0
IPM1H05B.XPOS : 0
IPM1H05B.YPOS : 0
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2626.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : -92.0371
Wien BDL (First Solenoid) (Gcm) : -1021.5
Wien BDL (Second Solenoid) (Gcm) : -1021.5
Wien angle (Horizontal) : 0
Wien BDL (Gcm) : -25
Wien HV Polarity (Horizontal) : POSITIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 147
Laser power Hall A : 0
Half-wave plate (off=out) : OUT
rotating waveplate : 349
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Right septum current : 480.948
Left septum current : 481.48
Target In : disabled
Target Out : enabled
Helium Pressure : disabled