NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 06:28:45 on December 17, 2011
Entry number 360372
keyword=Start_Run_1822,Run_type=Commission,target_type=Carbon,beam_e0=1.72,beam_fraster=off,beam_sraster=off,beam_current=1,leftarm_p=1.72,leftarm_theta=5.69,leftarm_sieve=out,septum_current=480,comment_text=carbon inelastic spectrum
Beginning-of-run EPICS data for Run Number 1822 at Sat Dec 17 06:28:41 EST 2011
Run_type=Commission
target_type=Carbon
beam_e0=1.72
beam_fraster=off
beam_sraster=off
beam_current=1
leftarm_p=1.72
leftarm_theta=5.69
leftarm_sieve=out
septum_current=480
comment_text=carbon inelastic spectrum
;This file is automatically generated from Prescales GUI.
;To generate this file, type "prescaleL" without quotes on a-onl@adaql2
;terminal then input the desired prescales and Save.
;T3 = L-arm scint trig (s1.AND.s2m)
;T4 = L-arm efficiency trigger
;T8 = 1024 Hz pulser or whatever
ps1=0,ps2=0,ps3=2,ps4=1,ps5=0,ps6=0,ps7=0,ps8=0
Left Arm Q1 momentum : 1.13332
Left Arm Q1 power supply : 852.636
Left Arm Q1 gauss meter : -0.07085
Left Arm Q2 power supply current : 699.938
Left Arm Q2 momentum : 1.6255
Left Arm Q2 gauss meter : 0.3706
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 576.81
Left Arm D1 momentum : 1.72003
Left Arm D1 NMR : 0.636535
Left Arm Q3 power supply current : 827.377
Left Arm Q3 momentum : 2.07822
Left Arm Q3 gauss meter : -0.41759
Left Arm Q3 power supply polarity : disabled
Left Arm B Field Hall Probe (D-G) : -0.6124
-----
Right Arm Q1 momentum : 1.57006
Right Arm Q1 power supply : 859.739
Right Arm Q1 gauss meter : -0.021508
Right Arm Q2 power supply current : 701.284
Right Arm Q2 momentum : 1.60861
Right Arm Q2 gauss meter : 0.3685
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 592.646
Right Arm D1 momentum : 1.71995
Right Arm D1 NMR : 0.638251
Right Arm Q3 power supply current : 825.388
Right Arm Q3 momentum : 1.53001
Right Arm Q3 gauss meter : 0.3665
Right Arm Q3 power supply polarity : disabled
Right Arm B Field Hall Probe (D-G) : -0.6296
-----
Left Arm Top VDC Current : 4.15039
Left Arm Bottom VDC Current : -9.08203
Left Arm Top VDC voltage : 4.00732
Left Arm Bottom VDC voltage : 3.99756
-----
Right Arm Top VDC Current : -2.14844
Right Arm Bottom VDC Current : -1.26953
Right Arm Top VDC voltage : 4.01562
Right Arm Bottom VDC voltage : 3.97363
-----
HacL_HPE1313A:0_Ch58 : -0.297852
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : -0.0224609
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm D1 momentum : 1.71995
Right Arm arm angle : 12.501
-----
Left VDC -DISC LVL Top : 3.90625
Left VDC -DISC LVL Bottom : 3.96191
Left VDC -DISC LVL Voltage1 : 4.96875
Left VDC -DISC LVL Voltage2 : -5.0625
Left VDC -DISC LVL Top Set : 4
Left VDC -DISC LVL Bottom Set : 4
-----
HacR_HPE1313A:0_Ch58 : -0.697266
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -1.02637
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.501
-----
IPM1C12.XPOS : -0.960511
IPM1C12.YPOS : 1.58263
IPM1H05A.XPOS : -0.139044
IPM1H05A.YPOS : -2.67296
IPM1H05B.XPOS : 0.872204
IPM1H05B.YPOS : -2.671
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2626.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : -92.0371
Wien BDL (First Solenoid) (Gcm) : -1021.5
Wien BDL (Second Solenoid) (Gcm) : -1021.5
Wien angle (Horizontal) : 0
Wien BDL (Gcm) : -25
Wien HV Polarity (Horizontal) : POSITIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 148
Laser power Hall A : 0
Half-wave plate (off=out) : OUT
rotating waveplate : 349
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Right septum current : 479.97
Left septum current : 480.554
Target In : disabled
Target Out : enabled
Helium Pressure : disabled