    Log entry time 06:32:04 on December 17, 2011

    Entry number 360376

    keyword=Start_Run_1823,Run_type=Commission,target_type=Carbon,beam_e0=1.72,beam_fraster=off,beam_sraster=off,beam_current=1,leftarm_p=1.72,leftarm_theta=5.69,leftarm_sieve=out,septum_current=480,comment_text=carbon inelastic spectrum
    Beginning-of-run EPICS data for Run Number 1823 at Sat Dec 17 06:32:01 EST 2011
    
    
    
    Run_type=Commission
    target_type=Carbon
    beam_e0=1.72
    beam_fraster=off
    beam_sraster=off
    beam_current=1
    leftarm_p=1.72
    leftarm_theta=5.69
    leftarm_sieve=out
    septum_current=480
    comment_text=carbon inelastic spectrum
    
    
    ;This file is automatically generated from Prescales GUI.
    ;To generate this file, type "prescaleL" without quotes on a-onl@adaql2
    ;terminal then input the desired prescales and Save.
    ;T3 = L-arm scint trig (s1.AND.s2m)
    ;T4 = L-arm efficiency trigger
    ;T8 = 1024 Hz pulser or whatever
    
    ps1=0,ps2=0,ps3=3,ps4=1,ps5=0,ps6=0,ps7=0,ps8=0
    
    
    Left Arm Q1 momentum : 1.13332
    Left Arm Q1 power supply : 852.636
    Left Arm Q1 gauss meter : -0.07084
    Left Arm Q2 power supply current : 699.939
    Left Arm Q2 momentum : 1.6255
    Left Arm Q2 gauss meter : 0.3705
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 576.817
    Left Arm D1 momentum : 1.72004
    Left Arm D1 NMR : 0.636536
    Left Arm Q3 power supply current : 827.383
    Left Arm Q3 momentum : 2.07823
    Left Arm Q3 gauss meter : -0.41759
    Left Arm Q3 power supply polarity : disabled
    Left Arm B Field Hall Probe (D-G) : -0.6125
    -----
    Right Arm Q1 momentum : 1.57006
    Right Arm Q1 power supply : 859.739
    Right Arm Q1 gauss meter : -0.02152
    Right Arm Q2 power supply current : 701.285
    Right Arm Q2 momentum : 1.60861
    Right Arm Q2 gauss meter : 0.3686
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 592.862
    Right Arm D1 momentum : 1.71978
    Right Arm D1 NMR : 0.63819
    Right Arm Q3 power supply current : 825.388
    Right Arm Q3 momentum : 1.53002
    Right Arm Q3 gauss meter : 0.3665
    Right Arm Q3 power supply polarity : disabled
    Right Arm B Field Hall Probe (D-G) : -0.6296
    -----
    Left Arm Top VDC Current : 4.05273
    Left Arm Bottom VDC Current : 15.3809
    Left Arm Top VDC voltage : 4.00586
    Left Arm Bottom VDC voltage : 3.99756
    -----
    Right Arm Top VDC Current : -4.58984
    Right Arm Bottom VDC Current : -2.44141
    Right Arm Top VDC voltage : 4.01611
    Right Arm Bottom VDC voltage : 3.97266
    -----
    HacL_HPE1313A:0_Ch58 : -0.297363
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : -0.0224609
    Left Arm Angle Floor Angle : 0
    Left Arm Angle Vernier : 0
    Left Arm Scattering Angle : -0.179
    -----
    Right Arm D1 momentum : 1.71978
    Right Arm arm angle : 12.501
    -----
    Left VDC -DISC LVL Top : 3.90674
    Left VDC -DISC LVL Bottom : 3.96289
    Left VDC -DISC LVL Voltage1 : 4.96924
    Left VDC -DISC LVL Voltage2 : -5.06201
    Left VDC -DISC LVL Top Set : 4
    Left VDC -DISC LVL Bottom Set : 4
    -----
    HacR_HPE1313A:0_Ch58 : -0.697266
    HacR_HPE1313A:0_Ch55 : 22.3145
    HacR_HPE1313A:0_Ch54 : -1.02686
    Right Arm Angle Floor Angle : 12.5
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 12.501
    -----
    IPM1C12.XPOS : -1.01893
    IPM1C12.YPOS : 1.57619
    IPM1H05A.XPOS : -0.144428
    IPM1H05A.YPOS : -2.66734
    IPM1H05B.XPOS : 0.862923
    IPM1H05B.YPOS : -2.66793
    Survey X offset bpmA : 0
    Survey Y offset bpmA : 0
    Survey X offset bpmB : 0
    Survey Y offset bpmB : 0
    -----
    Wien angle (Vertical) : 89.9999
    Wien Vertical BDL (Gcm) : 2626.6
    Wien HV Polarity : POSITIVE
    Wien electrode Voltage : 0
    Wien angle (Solenoids) : -92.0371
    Wien BDL (First Solenoid) (Gcm) : -1021.5
    Wien BDL (Second Solenoid) (Gcm) : -1021.5
    Wien angle (Horizontal) : 0
    Wien BDL (Gcm) : -25
    Wien HV Polarity (Horizontal) : POSITIVE
    Wien electrode Voltage (Horizontal) : 0
    Laser attenuation Hall A : 147
    Laser power Hall A : 0
    Half-wave plate (off=out) : OUT
    rotating waveplate : 349
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Delay Set : 8 windows
    Helicity Pattern Set : Quartet
    Helicity Clock Set : Free Clock
    Helicity Settle Read : 70
    Helicity Stable Read : 971.65
    Helicity Delay Read : 8 windows
    Helicity Pattern : Quartet
    Helicity Clock Read : Free Clock
    Helicity Frequency : 960.015
    Right septum current : 479.954
    Left septum current : 480.469
    Target In : disabled
    Target Out : enabled
    Helium Pressure : disabled