Log entry time 20:49:00 on December 17, 2011
Entry number 360564
keyword=End_of_Run_1881
****************************
Run Number: 1881
End of Run Comment:
Run_type=Commission,target_type=Carbon,beam_e0=1.72,beam_fraster=on,beam_sraster=off,beam_current=1,leftarm_p=1.431,leftarm_theta=5.69,leftarm_sieve=out,septum_current=402,comment_text=config B
PRESCALE FACTORS:ps1=0 ps2=0 ps3=0 ps4=0 ps5=0 ps6=0 ps7=0 ps8=1
EVENTS : [0]: 0 [+]: 0 [-]: 0
TIME : [0]: 0.210 mins [+]: 0.121 mins [-]: 0.121 mins
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 100.00% [+]: 100.00% [-]: 100.00%
TRIGGER RATES: PRES/REAL
T1[0] :T1: 0.0/343.6 Hz T2[0] :T2: 0.0/4.7 Hz T3[0] :T3: 0.0/282.6 Hz T4[0] :T4: 0.0/6.8 Hz T5[0] :T5: 0.0/0.0 Hz T6[0] :T6: 0.0/3842.6 Hz T7[0] :T7: 0.0/103876.6 Hz T8[0] :T8:1024.0/1024.0 Hz
T1[+] :T1: 0.0/337.5 Hz T2[+] :T2: 0.0/4.1 Hz T3[+] :T3: 0.0/283.8 Hz T4[+] :T4: 0.0/7.6 Hz T5[+] :T5: 0.0/0.0 Hz T6[+] :T6: 0.0/3843.1 Hz T7[+] :T7: 0.0/103849.1 Hz T8[+] :T8:1024.0/1024.0 Hz
T1[-] :T1: 0.0/352.3 Hz T2[-] :T2: 0.0/5.6 Hz T3[-] :T3: 0.0/284.4 Hz T4[-] :T4: 0.0/7.0 Hz T5[-] :T5: 0.0/0.0 Hz T6[-] :T6: 0.0/3833.0 Hz T7[-] :T7: 0.0/103892.6 Hz T8[-] :T8:1024.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] :T1: 0/4324 T2[0] :T2: 0/59 T3[0] :T3: 0/3556 T4[0] :T4: 0/86 T5[0] :T5: 0/0 T6[0] :T6: 0/48355 T7[0] :T7: 0/1307182 T8[0] :T8: 12886/12886
T1[+] :T1: 0/2452 T2[+] :T2: 0/30 T3[+] :T3: 0/2062 T4[+] :T4: 0/55 T5[+] :T5: 0/0 T6[+] :T6: 0/27919 T7[+] :T7: 0/754427 T8[+] :T8: 7439/7439
T1[-] :T1: 0/2558 T2[-] :T2: 0/41 T3[-] :T3: 0/2065 T4[-] :T4: 0/51 T5[-] :T5: 0/0 T6[-] :T6: 0/27834 T7[-] :T7: 0/754439 T8[-] :T8: 7436/7436
AVERAGE CURRENT
BCM x1 : -0.2153uA BCM x3 : 3.1664 uA BCM x10: 1.2816 uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = -2.95778 seconds
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 1E+39 ppm BCM u3 : 7620 ppm BCM u10:1.099E+04 ppm
BCM d1 : 1E+39 ppm BCM d3 : 1E+39 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0] : -3.838E-06 BCM u3 [0] : 8.074E-05 BCM u10[0] : 3.261E-05
BCM u1 [+] : -2.216E-06 BCM u3 [+] : 4.703E-05 BCM u10[+] : 1.904E-05
BCM u1 [-] : -2.215E-06 BCM u3 [-] : 4.63E-05 BCM u10[-] : 1.862E-05
BCM d1 [0] : -1.58E-06 BCM d3 [0] : -1.05E-06 BCM d10[0] : -3.571E-07
BCM d1 [+] : -9.123E-07 BCM d3 [+] : -6.061E-07 BCM d10[+] : -2.062E-07
BCM d1 [-] : -9.12E-07 BCM d3 [-] : -6.059E-07 BCM d10[-] : -2.061E-07
****************************
End-of-run EPICS data for Run Number 1881 at Sat Dec 17 20:48:58 EST 2011
Left Arm Top VDC Current : -0.341797
Left Arm Bottom VDC Current : -26.3184
Left Arm Top VDC voltage : 4.00439
Left Arm Bottom VDC voltage : 3.99902
-----
Right Arm Top VDC Current : -4.00391
Right Arm Bottom VDC Current : -0.878906
Right Arm Top VDC voltage : 4.01611
Right Arm Bottom VDC voltage : 3.97266
-----
Left Arm Q1 momentum : 0.942509
Left Arm Q1 power supply : 709.079
Left Arm Q1 gauss meter : -0.059
Left Arm Q2 gauss meter : 0.3083
Left Arm Q2 power supply current : 581.901
Left Arm Q2 momentum : 1.35137
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 476.276
Left Arm D1 momentum : 1.43097
Left Arm D1 NMR : 0.529636
Left Arm arm angle : -0.179
Left Arm Q3 gauss meter : -0.34753
Left Arm Q3 power supply current : 688.526
Left Arm Q3 momentum : 1.72945
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.30634
Right Arm Q1 power supply : 715.328
Right Arm Q1 gauss meter : -0.017962
Right Arm Q2 power supply current : 583.434
Right Arm Q2 momentum : 1.33828
Right Arm Q2 gauss meter : 0.3066
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 490.375
Right Arm D1 momentum : 1.43102
Right Arm D1 NMR : 0.531034
Right Arm arm angle : 12.501
Right Arm Q3 power supply current : 686.759
Right Arm Q3 momentum : 1.27304
Right Arm Q3 gauss meter : 0.305
Right Arm Q3 power supply polarity : disabled
-----
HacL_HPE1313A:0_Ch58 : -0.29834
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : -0.0229492
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Left VDC -DISC LVL Top : 3.90479
Left VDC -DISC LVL Bottom : 3.96094
Left VDC -DISC LVL Voltage1 : 4.96777
Left VDC -DISC LVL Voltage2 : -5.06152
-----
Right Arm Collimator : 0.0565918
HacR_HPE1313A:0_Ch58 : -0.696777
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -1.02588
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.501