NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 05:55:21 on December 18, 2011
Entry number 360685
keyword=Start_Run_1917,Run_type=Commission,target_type=Carbon,beam_e0=1.72,beam_fraster=off,beam_sraster=off,beam_current=1,leftarm_p=1.211,leftarm_theta=5.69,leftarm_sieve=out,septum_current=342,comment_text=Carbon Scan 6a
Beginning-of-run EPICS data for Run Number 1917 at Sun Dec 18 05:55:15 EST 2011
Run_type=Commission
target_type=Carbon
beam_e0=1.72
beam_fraster=off
beam_sraster=off
beam_current=1
leftarm_p=1.211
leftarm_theta=5.69
leftarm_sieve=out
septum_current=342
comment_text=Carbon Scan 6a
ps1=0,ps2=0,ps3=1,ps4=1,ps5=0,ps6=0,ps7=0,ps8=0
Left Arm Q1 momentum : 0.797693
Left Arm Q1 power supply : 600.13
Left Arm Q1 gauss meter : -0.04993
Left Arm Q2 power supply current : 492.038
Left Arm Q2 momentum : 1.14268
Left Arm Q2 gauss meter : 0.2609
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 401.871
Left Arm D1 momentum : 1.211
Left Arm D1 NMR : 0.448288
Left Arm Q3 power supply current : 582.807
Left Arm Q3 momentum : 1.4639
Left Arm Q3 gauss meter : -0.29424
Left Arm Q3 power supply polarity : disabled
Left Arm B Field Hall Probe (D-G) : -0.4314
-----
Right Arm Q1 momentum : 1.10591
Right Arm Q1 power supply : 605.577
Right Arm Q1 gauss meter : -0.015235
Right Arm Q2 power supply current : 493.723
Right Arm Q2 momentum : 1.1325
Right Arm Q2 gauss meter : 0.2592
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 414.166
Right Arm D1 momentum : 1.211
Right Arm D1 NMR : 0.449389
Right Arm Q3 power supply current : 581.215
Right Arm Q3 momentum : 1.07739
Right Arm Q3 gauss meter : 0.2582
Right Arm Q3 power supply polarity : disabled
Right Arm B Field Hall Probe (D-G) : -0.4432
-----
Left Arm Top VDC Current : 3.75977
Left Arm Bottom VDC Current : 32.6172
Left Arm Top VDC voltage : 4.01123
Left Arm Bottom VDC voltage : 3.99854
-----
Right Arm Top VDC Current : 1.07422
Right Arm Bottom VDC Current : 0.488281
Right Arm Top VDC voltage : 4.01562
Right Arm Bottom VDC voltage : 3.9707
-----
Hall A current reading : 1.02
BCM Pre Gain 1 A : 24
BCM Pre Gain 2 A : 25
Mag Div by 2^n A : 1028
BCM Pre Gain 1 B : 24
BCM Pre Gain 2 B : 25
Mag Div by 2^n B : 1028
-----
HacL_HPE1313A:0_Ch58 : -0.297852
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.0214844
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm D1 momentum : 1.211
Right Arm arm angle : 12.501
-----
Left VDC -DISC LVL Top : 3.90527
Left VDC -DISC LVL Bottom : 3.96045
Left VDC -DISC LVL Voltage1 : 4.9668
Left VDC -DISC LVL Voltage2 : -5.0625
Left VDC -DISC LVL Top Set : 4
Left VDC -DISC LVL Bottom Set : 4
-----
HacR_HPE1313A:0_Ch58 : -0.696777
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -1.02588
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.501
-----
IPM1C12.XPOS : -0.83655
IPM1C12.YPOS : 0.895256
IPM1H05A.XPOS : -1.41169
IPM1H05A.YPOS : -0.506737
IPM1H05B.XPOS : -0.970155
IPM1H05B.YPOS : -0.883867
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2626.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : -92.0371
Wien BDL (First Solenoid) (Gcm) : -1021.5
Wien BDL (Second Solenoid) (Gcm) : -1021.5
Wien angle (Horizontal) : 0
Wien BDL (Gcm) : -25
Wien HV Polarity (Horizontal) : POSITIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 155
Laser power Hall A : 0
Half-wave plate (off=out) : IN
rotating waveplate : 6478
Beam Half-wave plate (off=out) : IN
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Right septum current : 341.957
Left septum current : 342.077
Target In : disabled
Target Out : enabled
Helium Pressure : disabled