    keyword=NOTE: last few runs had Target OUT, not C target (Runs 2036-2041/21136-21141)

    Realized during Runs 2041/21141 of current scan that the C target had been taken OUT during the earlier BCM calibration point and not put back in ... therefore the runs 2036-2041 (L) and 21136-21141 are incorrectly labeled as having C target IN, but they are most definitely TARGET OUT.

    These will be useful runs for the current scan, though, since the goal is to get accurate C elastic cross sections extracted at each current ... now the data for Empty target is well measured. :)